Literature DB >> 17955344

CFD analysis in an anatomically realistic coronary artery model based on non-invasive 3D imaging: comparison of magnetic resonance imaging with computed tomography.

Leonid Goubergrits1, Ulrich Kertzscher, Bastian Schöneberg, Ernst Wellnhofer, Christoph Petz, Hans-Christian Hege.   

Abstract

Computational fluid dynamics (CFD) methods based on in vivo three-dimensional vessel reconstructions have recently been shown to provide prognostically relevant hemodynamic data. However, the geometry reconstruction and the assessment of clinically relevant hemodynamic parameters may depend on the used imaging modality. This study compares geometric reconstruction and calculated wall shear stress (WSS) values based on magnetic resonance imaging (MRI) and computed tomography (CT). Both imaging methods were applied to a same 2.5-fold upscale silicon model of the left coronary artery (LCA) main bifurcation. The original model is an optically digitized post mortem vessel cast. This digitized geometry is considered as a "gold standard" or original geometry for the MRI versus CT comparative study. The use of the upscale model allowed generating a high resolution CT raw data set with voxel size of 0.156 x 0.156 x 0.36 mm(3) and a high resolution MRI data set with an equivalent voxel size of 0.196 x 0.196 x 0.196 mm(3) for corresponding in vivo conditions. MRI based reconstruction achieved a mean Hausdorff surface distance of 0.1 mm to the original geometry. This is 2.5 times better than CT based reconstruction with mean Hausdorff surface distance of 0.252 mm. A comparison of the calculated mean WSS shows good correlation (r = 0.97) and good agreement among the three modalities with a WSS of 0.65 Pa in the original model, of 0.68 Pa in the CT based model and of 0.67 Pa in the MRI based model.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17955344     DOI: 10.1007/s10554-007-9275-z

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  38 in total

1.  Estimation of wall shear stress in bypass grafts with computational fluid dynamics method.

Authors:  L Goubergrits; K Affeld; E Wellnhofer; T Holmer
Journal:  Int J Artif Organs       Date:  2001-03       Impact factor: 1.595

Review 2.  Endothelial responses to mechanical stress: where is the mechanosensor?

Authors:  Mir H Ali; Paul T Schumacker
Journal:  Crit Care Med       Date:  2002-05       Impact factor: 7.598

Review 3.  Regulation of endothelium-derived vasoactive autacoid production by hemodynamic forces.

Authors:  Rudi Busse; Ingrid Fleming
Journal:  Trends Pharmacol Sci       Date:  2003-01       Impact factor: 14.819

4.  Hemodynamic shear stress and its role in atherosclerosis.

Authors:  A M Malek; S L Alper; S Izumo
Journal:  JAMA       Date:  1999-12-01       Impact factor: 56.272

5.  Validated computation of physiologic flow in a realistic coronary artery branch.

Authors:  K Perktold; M Hofer; G Rappitsch; M Loew; B D Kuban; M H Friedman
Journal:  J Biomech       Date:  1998-03       Impact factor: 2.712

6.  MR angiography at 3T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils.

Authors:  Charles B L M Majoie; Marieke E Sprengers; Willem Jan J van Rooij; Cristina Lavini; Menno Sluzewski; Jeroen C van Rijn; Gerard J den Heeten
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

7.  Flow and stress characteristics in rigid walled and compliant carotid artery bifurcation models.

Authors:  K Perktold; E Thurner; T Kenner
Journal:  Med Biol Eng Comput       Date:  1994-01       Impact factor: 2.602

Review 8.  Localization of atherosclerosis: role of hemodynamics.

Authors:  S G Frangos; V Gahtan; B Sumpio
Journal:  Arch Surg       Date:  1999-10

9.  Analysis of haemodynamic disturbance in the atherosclerotic carotid artery using computational fluid dynamics.

Authors:  Daniel Birchall; Azfar Zaman; Jacob Hacker; Gavin Davies; David Mendelow
Journal:  Eur Radiol       Date:  2006-01-10       Impact factor: 5.315

Review 10.  Prediction of sites of coronary atherosclerosis progression: In vivo profiling of endothelial shear stress, lumen, and outer vessel wall characteristics to predict vascular behavior.

Authors:  Peter H Stone; Ahmet Umit Coskun; Yerem Yeghiazarians; Scott Kinlay; Jeffrey J Popma; Richard E Kuntz; Charles L Feldman
Journal:  Curr Opin Cardiol       Date:  2003-11       Impact factor: 2.161

View more
  12 in total

1.  Effect of the degree of LAD stenosis on "competitive flow" and flow field characteristics in LIMA-to-LAD bypass surgery.

Authors:  Abigail Swillens; Marloes De Witte; Håvard Nordgaard; Lasse Løvstakken; Denis Van Loo; Bram Trachet; Jan Vierendeels; Patrick Segers
Journal:  Med Biol Eng Comput       Date:  2012-06-16       Impact factor: 2.602

Review 2.  New X-ray imaging modalities and their integration with intravascular imaging and interventions.

Authors:  H Hetterich; T Redel; G Lauritsch; C Rohkohl; J Rieber
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-08       Impact factor: 2.357

3.  Tortuosity of coronary bifurcation as a potential local risk factor for atherosclerosis: CFD steady state study based on in vivo dynamic CT measurements.

Authors:  M Malvè; A M Gharib; S K Yazdani; G Finet; M A Martínez; R Pettigrew; J Ohayon
Journal:  Ann Biomed Eng       Date:  2014-07-02       Impact factor: 3.934

4.  Development of an In Vitro Model to Characterize the Effects of Transcatheter Aortic Valve on Coronary Artery Flow.

Authors:  Joseph Calderan; Wenbin Mao; Eric Sirois; Wei Sun
Journal:  Artif Organs       Date:  2015-10-29       Impact factor: 3.094

5.  Assessment of endothelial shear stress in patients with mild or intermediate coronary stenoses using coronary computed tomography angiography: comparison with invasive coronary angiography.

Authors:  Dexiao Huang; Takashi Muramatsu; Yingguang Li; Wenjie Yang; Yasuomi Nagahara; Miao Chu; Pieter Kitslaar; Masayoshi Sarai; Yukio Ozaki; Yiannis S Chatzizisis; Fuhua Yan; Johan H C Reiber; Renhua Wu; Jun Pu; Shengxian Tu
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-31       Impact factor: 2.357

6.  The effects of aortic coarctation on cerebral hemodynamics and its importance in the etiopathogenesis of intracranial aneurysms.

Authors:  Pankaj K Singh; Alberto Marzo; Cristina Staicu; Matt G William; Iain Wilkinson; Patricia V Lawford; Daniel A Rufenacht; Philippe Bijlenga; Alejandro F Frangi; Rodney Hose; Umang J Patel; Stuart C Coley
Journal:  J Vasc Interv Neurol       Date:  2010-01

7.  Numerical study to indicate the vulnerability of plaques using an idealized 2D plaque model based on plaque classification in the human coronary artery.

Authors:  Wookjin Lee; Gyu Jin Choi; Seong Wook Cho
Journal:  Med Biol Eng Comput       Date:  2016-12-09       Impact factor: 2.602

8.  Influence of the Accuracy of Angiography-Based Reconstructions on Velocity and Wall Shear Stress Computations in Coronary Bifurcations: A Phantom Study.

Authors:  Jelle T C Schrauwen; Antonios Karanasos; Nienke S van Ditzhuijzen; Jean-Paul Aben; Antonius F W van der Steen; Jolanda J Wentzel; Frank J H Gijsen
Journal:  PLoS One       Date:  2015-12-21       Impact factor: 3.240

9.  Coronary computed tomography angiography based assessment of endothelial shear stress and its association with atherosclerotic plaque distribution in-vivo.

Authors:  Holger Hetterich; Ahmad Jaber; Moritz Gehring; Adrian Curta; Fabian Bamberg; Nenad Filipovic; Johannes Rieber
Journal:  PLoS One       Date:  2015-01-30       Impact factor: 3.240

10.  The role of computational fluid dynamics in the management of unruptured intracranial aneurysms: a clinicians' view.

Authors:  Pankaj K Singh; Alberto Marzo; Stuart C Coley; Guntram Berti; Philippe Bijlenga; Patricia V Lawford; Mari-Cruz Villa-Uriol; Daniel A Rufenacht; Keith M McCormack; Alejandro Frangi; Umang J Patel; D Rodney Hose
Journal:  Comput Intell Neurosci       Date:  2009-08-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.