Literature DB >> 1795503

Four-channel telemetry system for in vivo measurement of hip joint forces.

F Graichen1, G Bergmann.   

Abstract

The long-term loosening of artificial hip joints remains a serious clinical problem. Optimization of implant design and material will improve the fixation, but it requires a detailed knowledge of the forces which act on the implant. A four-channel telemetric transmitter was developed and arranged completely inside a hermetically closed artificial hip joint. This permits long term in vivo measurements of the three-dimensional forces without endangering the patient. The external telemetry system consists of an inductive power supply, an RF receiver, a microcomputer with hardware extension and a VHS video system. The personal computer offers real-time data processing of three orthogonal force components as well as slow motion analysis of recorded measurements. After several years of animal tests, two instrumented prostheses were implanted in the first patient (male) in May and August of 1988. In March 1990 a third prosthesis was implanted in a second patient (female). Joint force measurements have regularly been performed from the first post-operative day until now for several kinds of activity.

Entities:  

Mesh:

Year:  1991        PMID: 1795503     DOI: 10.1016/0141-5425(91)90016-z

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  9 in total

1.  Hip joint contact forces during stumbling.

Authors:  G Bergmann; F Graichen; A Rohlmann
Journal:  Langenbecks Arch Surg       Date:  2003-11-19       Impact factor: 3.445

2.  Telemetry system for monitoring anterior cruciate ligament graft forces in vivo.

Authors:  E L McKee; D P Lindsey; M L Hull; S M Howell
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

3.  Biopolymer augmentation of the lag screw in the treatment of femoral neck fractures--a biomechanical in-vitro study.

Authors:  A Paech; E Wilde; A P Schulz; G Heinrichs; R Wendlandt; C Queitsch; B Kienast; Ch Jürgens
Journal:  Eur J Med Res       Date:  2010-04-08       Impact factor: 2.175

4.  The History of Biomechanics in Total Hip Arthroplasty.

Authors:  Jan Van Houcke; Vikas Khanduja; Christophe Pattyn; Emmanuel Audenaert
Journal:  Indian J Orthop       Date:  2017 Jul-Aug       Impact factor: 1.251

5.  In vivo measured joint friction in hip implants during walking after a short rest.

Authors:  Philipp Damm; Alwina Bender; Georg Duda; Georg Bergmann
Journal:  PLoS One       Date:  2017-03-28       Impact factor: 3.240

Review 6.  Wireless Technologies for Implantable Devices.

Authors:  Bradley D Nelson; Salil Sidharthan Karipott; Yvonne Wang; Keat Ghee Ong
Journal:  Sensors (Basel)       Date:  2020-08-16       Impact factor: 3.576

7.  Development of a Wireless Telemetry Sensor Device to Measure Load and Deformation in Orthopaedic Applications.

Authors:  William D Anderson; Sydney L M Wilson; David W Holdsworth
Journal:  Sensors (Basel)       Date:  2020-11-27       Impact factor: 3.576

8.  High-tech hip implant for wireless temperature measurements in vivo.

Authors:  Georg Bergmann; Friedmar Graichen; Jörn Dymke; Antonius Rohlmann; Georg N Duda; Philipp Damm
Journal:  PLoS One       Date:  2012-08-22       Impact factor: 3.240

9.  Smart implants in orthopedic surgery, improving patient outcomes: a review.

Authors:  Eric H Ledet; Benjamin Liddle; Katerina Kradinova; Sara Harper
Journal:  Innov Entrep Health       Date:  2018-08-29
  9 in total