Literature DB >> 17954307

Mechanical strength and stiffness of biodegradable and titanium osteofixation systems.

Gerrit J Buijs1, Eduard B van der Houwen, Boudewijn Stegenga, Rudulf R M Bos, Gijsbertus J Verkerke.   

Abstract

PURPOSE: To present relevant mechanical data to simplify the selection of an osteofixation system for situations requiring immobilization in oral and maxillofacial surgery.
MATERIALS AND METHODS: Seven biodegradable and 2 titanium osteofixation systems were investigated. The plates and screws were fixed to 2 polymethylmethacrylate (PMMA) blocks to simulate bone segments. The plates and screws were subjected to tensile, side bending, and torsion tests. During tensile tests, the strength of the osteofixation system was monitored. The stiffness was calculated for the tensile, side bending, and torsion tests.
RESULTS: The 2 titanium systems (1.5 mm and 2.0 mm) presented significantly higher tensile strength and stiffness compared with the 7 biodegradable systems (2.0 mm, 2.1 mm, and 2.5 mm). The 2.0 mm titanium system showed significantly higher side bending and torsion stiffness than the other 8 systems.
CONCLUSION: Based on the results of the current study, it can be concluded that the titanium osteofixation systems were (significantly) stronger and stiffer than the biodegradable systems. The BioSorb FX (Linvatec Biomaterials Ltd, Tampere, Finland), LactoSorb (Walter Lorenz Surgical Inc, Jacksonville, FL), and Inion (Inion Ltd, Tampere, Finland) 2.5 mm systems have high mechanical device strength and stiffness compared with the investigated biodegradable osteofixation systems. With the cross-sectional surface taken into account, the Biosorb FX system (with its subtle design) proves to be the far more superior system. The Resorb X (Gebrüder Martin GmbH & Co, Tuttlingen, Germany) and MacroPore (MacroPore Biosurgery Inc, Memphis, TN) systems present to be, at least from a mechanical point of view, the least strong and stiff systems in the test.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17954307     DOI: 10.1016/j.joms.2007.04.010

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  11 in total

1.  Evaluation and reduction of magnetic resonance imaging artefacts induced by distinct plates for osseous fixation: an in vitro study @ 3 T.

Authors:  Carsten Rendenbach; Max Schoellchen; Julie Bueschel; Tobias Gauer; Jan Sedlacik; Daniel Kutzner; Pekka K Vallittu; Max Heiland; Ralf Smeets; Jens Fiehler; Susanne Siemonsen
Journal:  Dentomaxillofac Radiol       Date:  2018-05-23       Impact factor: 2.419

2.  Foreign-Body Granuloma after Metacarpal Fracture Treatment with Absorbable Implants.

Authors:  Jung-Sik Choi; Jung-Ho Lee; Sue-Min Kim; Young-Jin Kim; Young-Joon Jun
Journal:  Arch Plast Surg       Date:  2015-07-14

3.  Cost-Effectiveness of a Biodegradable Compared to a Titanium Fixation System in Maxillofacial Surgery: A Multicenter Randomized Controlled Trial.

Authors:  N B van Bakelen; K M Vermeulen; G J Buijs; J Jansma; J G A M de Visscher; Th J M Hoppenreijs; J E Bergsma; B Stegenga; R R M Bos
Journal:  PLoS One       Date:  2015-07-20       Impact factor: 3.240

Review 4.  The Use of Poly-d,l-lactic Acid (PDLLA) Devices for Bone Augmentation Techniques: A Systematic Review.

Authors:  Marco Annunziata; Livia Nastri; Gennaro Cecoro; Luigi Guida
Journal:  Molecules       Date:  2017-12-13       Impact factor: 4.411

Review 5.  Overview of innovative advances in bioresorbable plate systems for oral and maxillofacial surgery.

Authors:  Takahiro Kanno; Shintaro Sukegawa; Yoshihiko Furuki; Yoshiki Nariai; Joji Sekine
Journal:  Jpn Dent Sci Rev       Date:  2018-04-05

6.  Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up.

Authors:  Barzi Gareb; Nico B van Bakelen; Léon Driessen; Pieter Buma; Jeroen Kuipers; Dirk W Grijpma; Arjan Vissink; Ruud R M Bos; Baucke van Minnen
Journal:  Bioact Mater       Date:  2022-01-19

7.  To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study.

Authors:  Rishi K Bali; Parveen Sharma; Shalu Jindal; Shivani Gaba
Journal:  Natl J Maxillofac Surg       Date:  2013-07

8.  Evaluation of the Fatigue Performance and Degradability of Resorbable PLDLLA-TMC Osteofixations.

Authors:  Constantin Landes; Alexander Ballon; Shahram Ghanaati; Daniel Ebel; Dieter Ulrich; Uwe Spohn; Ute Heunemann; Robert Sader; Raimund Jaeger
Journal:  Open Biomed Eng J       Date:  2013-11-29

9.  Biodegradable magnesium alloy (WE43) in bone-fixation plate and screw.

Authors:  Soo-Hwan Byun; Ho-Kyung Lim; Kwang-Hee Cheon; Sung-Mi Lee; Hyoun-Ee Kim; Jong-Ho Lee
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-02-12       Impact factor: 3.368

10.  Comparison of the mechanical properties of biodegradable and titanium osteosynthesis systems used in oral and maxillofacial surgery.

Authors:  Barzi Gareb; Charlotte C Roossien; Nico B van Bakelen; Gijsbertus J Verkerke; Arjan Vissink; Ruud R M Bos; Baucke van Minnen
Journal:  Sci Rep       Date:  2020-10-23       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.