Literature DB >> 17952720

Sixteen-row multislice computerized tomography angiography in the postoperative evaluation of patients with intracranial aneurysms.

W Chen1, Y Yang, J Qiu, Y Peng, W Xing.   

Abstract

The goal of this study was to assess the diagnostic accuracy of 16-row multislice computed tomography angiography (CTA) compared with digital subtraction angiography (DSA) in the detection of aneurysm remnants and arterial patency after clipping of intracranial aneurysms. Thirty-seven consecutive patients with 40 clipped aneurysms (39 of which had ruptured) were studied with the aid of postoperative CTA and DSA. CTA was performed with a 16-row multislice CT scanner by using collimation of 0.75 mm. Two neuroradiologists evaluated the image quality of CTA and the presence of the residual aneurysms with a 5-point rating scale. DSA was considered a reference standard. Two aneurysms with incomplete closure were identified by the 16-slice CTA reconstructions. With 16-slice CTA, there were no false-positive results of an aneurysm with incomplete closure in any patient. Arterial patency could be reliably evaluated close to the clip. The sensitivity, specificity, and accuracy of 16-slice CTA for aneurysm occlusion and arterial patency were 100%[97.5% confidence interval (CI): 15.8 - 100%], 100% (97.5% CI: 90.7 - 100%) and 100% (97.5% CI: 91.2 - 100%), respectively. The positive and negative predictive values were 100 and 100%, respectively. The mean duration of the examination was 12 min for CTA and 40 min for DSA (p < 0.05). Sixteen-slice CTA was highly cost effective (p < 0.05). Sixteen-slice CTA is a valuable non-invasive diagnostic modality for the assessment of aneurysm remnants and arterial patency in patients after aneurysm clipping. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm.

Entities:  

Mesh:

Year:  2008        PMID: 17952720     DOI: 10.1080/02688690701630108

Source DB:  PubMed          Journal:  Br J Neurosurg        ISSN: 0268-8697            Impact factor:   1.596


  3 in total

1.  256-row multislice CT angiography in the postoperative evaluation of cerebral aneurysms treated with titanium clips: using three-dimensional rotational angiography as the standard of reference.

Authors:  Hye Jeong Kim; Dae Young Yoon; Eun Soo Kim; Eun Joo Yun; Hong Jun Jeon; Jong Young Lee; Byung-Moon Cho
Journal:  Eur Radiol       Date:  2019-12-16       Impact factor: 5.315

2.  Evaluation of the yield of post-clipping angiography and nationwide current practice.

Authors:  N Scheer; R Ghaznawi; M A A van Walderveen; R W Koot; P W A Willems
Journal:  Acta Neurochir (Wien)       Date:  2019-02-19       Impact factor: 2.216

3.  Applications of multislice CT angiography in the surgical clipping and endovascular coiling of intracranial aneurysms.

Authors:  Wenhua Chen; Yilin Yang; Wei Xing; Ya Peng; Jianguo Qiu; Zhongming He; Qi Wang
Journal:  J Biomed Res       Date:  2010-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.