Literature DB >> 17951856

Monte Carlo based water/medium stopping-power ratios for various ICRP and ICRU tissues.

José M Fernández-Varea1, Pablo Carrasco, Vanessa Panettieri, Lorenzo Brualla.   

Abstract

Water/medium stopping-power ratios, s(w,m), have been calculated for several ICRP and ICRU tissues, namely adipose tissue, brain, cortical bone, liver, lung (deflated and inflated) and spongiosa. The considered clinical beams were 6 and 18 MV x-rays and the field size was 10 x 10 cm(2). Fluence distributions were scored at a depth of 10 cm using the Monte Carlo code PENELOPE. The collision stopping powers for the studied tissues were evaluated employing the formalism of ICRU Report 37 (1984 Stopping Powers for Electrons and Positrons (Bethesda, MD: ICRU)). The Bragg-Gray values of s(w,m) calculated with these ingredients range from about 0.98 (adipose tissue) to nearly 1.14 (cortical bone), displaying a rather small variation with beam quality. Excellent agreement, to within 0.1%, is found with stopping-power ratios reported by Siebers et al (2000a Phys. Med. Biol. 45 983-95) for cortical bone, inflated lung and spongiosa. In the case of cortical bone, s(w,m) changes approximately 2% when either ICRP or ICRU compositions are adopted, whereas the stopping-power ratios of lung, brain and adipose tissue are less sensitive to the selected composition. The mass density of lung also influences the calculated values of s(w,m), reducing them by around 1% (6 MV) and 2% (18 MV) when going from deflated to inflated lung.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17951856     DOI: 10.1088/0031-9155/52/21/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  PRIMO: a graphical environment for the Monte Carlo simulation of Varian and Elekta linacs.

Authors:  M Rodriguez; J Sempau; L Brualla
Journal:  Strahlenther Onkol       Date:  2013-09-06       Impact factor: 3.621

2.  Accurate estimation of dose distributions inside an eye irradiated with 106Ru plaques.

Authors:  L Brualla; J Sempau; F J Zaragoza; A Wittig; W Sauerwein
Journal:  Strahlenther Onkol       Date:  2012-11-18       Impact factor: 3.621

3.  Monte Carlo Computation of Dose-Volume Histograms in Structures at Risk of an Eye Irradiated with Heterogeneous Ruthenium-106 Plaques.

Authors:  Francisco J Zaragoza; Marion Eichmann; Dirk Flühs; Beate Timmermann; Lorenzo Brualla
Journal:  Ocul Oncol Pathol       Date:  2020-07-20

4.  The photon dose calculation algorithm used in breast radiotherapy has significant impact on the parameters of radiobiological models.

Authors:  Saskia Petillion; Ans Swinnen; Gilles Defraene; Karolien Verhoeven; Caroline Weltens; Frank Van den Heuvel
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.