Literature DB >> 17950071

A comparative analysis of expanded polytetrafluoroethylene and small intestinal submucosa--implications for patch repair in ventral herniorrhaphy.

Thomas P Rauth1, Benjamin K Poulose, Lillian B Nanney, Michael D Holzman.   

Abstract

BACKGROUND: Small intestinal submucosa and expanded polytetrafluoroethylene are commonly used as adjuncts to repair in ventral herniorrhaphy. Despite their overlapping indications, the physical characteristics of the two materials are quite distinct. This study compares the in vivo properties of two bioprosthetic products, small intestinal submucosa (SiS Gold; Cook Biotech, West Lafayette, IN) and lyophilized small intestinal submucosa (LyoSiS; Cook Biotech), with expanded polytetrafluoroethylene (ePTFE; W.L. Gore and Associates, Flagstaff, AZ).
METHODS: Six pigs underwent placement of duplicate samples of each material (SiS Gold, LyoSiS, and ePTFE) within the abdomen as peritoneal onlays (total of six samples per pig). Gross characteristics were evaluated and random samples harvested for histological analysis at 8 wk following implantation. The percentage of contraction was determined by comparing pre-implant to post-implant area. Neovascularity (percent area blood vessels, %A(bv)) was quantitatively assessed by immunohistochemical staining with an endothelial marker, CD-31 antibody. Sites of active collagen deposition were identified and distinguished from pre-existing collagen using a pro-collagen antibody to characterize tissue incorporation and remodeling.
RESULTS: Compared with the original area of 22.75 cm(2), significant contraction was observed in SiS Gold, LyoSiS, and ePTFE at 8 wk (post-implant area; 7.6 cm(2), 5.7 cm(2), and 11.2 cm(2) respectively, P < 0.0001). The post-implant areas represent contraction of 67% for SiS Gold, 75% for LyoSiS, and 51% for ePTFE. The ePTFE implants experienced significantly less contraction than both the SiS Gold and LyoSiS implants (P = 0.002). No statistical difference in contraction was noted when SiS was compared with LyoSiS. Compared to SiS Gold, LyoSiS had a higher density of capillary ingrowth (2.7% A(bv)versus 2.2% A(bv), P = 0.01). As expected, vascular ingrowth was absent from the ePTFE samples. Qualitative analysis with pro-collagen antibody revealed new collagen deposition within the lamellar matrix of both SiS Gold and LyoSiS. In contrast, a similar analysis of ePTFE demonstrated a pattern of collagen encapsulation compared with the tissue infiltration and incorporation observed with SIS grafts.
CONCLUSION: The host response to ePTFE, SiS Gold and LyoSiS differs at 8 wk following implantation; SiS Gold and LyoSiS undergo tissue ingrowth and remodeling whereas ePTFE undergoes little or no incorporation or morphological change. The physical properties of the materials differ as well; SiS Gold, and LyoSiS experience significantly more contraction than ePTFE. Future comparative analysis may help determine which characteristic, contraction or incorporation, contributes more to long-term success in the patch repair of ventral hernia.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17950071     DOI: 10.1016/j.jss.2007.03.079

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  9 in total

1.  Use of porcine small intestine submucosa as a prosthetic material for laparoscopic hernia repair in infected and potentially contaminated fields: long-term follow-up assessment.

Authors:  Morris Franklin; Karla Russek
Journal:  Surg Endosc       Date:  2011-05       Impact factor: 4.584

2.  Polypropylene, polyester or polytetrafluoroethylene-is there an ideal material for mesh augmentation at the esophageal hiatus? Results from an experimental study in a porcine model.

Authors:  B P Müller-Stich; J D Senft; F Lasitschka; M Shevchenko; A T Billeter; T Bruckner; H G Kenngott; L Fischer; T Gehrig
Journal:  Hernia       Date:  2014-08-27       Impact factor: 4.739

3.  Use of porcine small intestine submucosa as a prosthetic material for laparoscopic hernia repair in infected and potentially contaminated fields: long-term follow up assessment; Surg Endosc (2008) 22: 1941-1946.

Authors:  Alexander H Petter-Puchner; René H Fortelny
Journal:  Surg Endosc       Date:  2009-07-25       Impact factor: 4.584

4.  Adhesive performance of biomimetic adhesive-coated biologic scaffolds.

Authors:  John L Murphy; Laura Vollenweider; Fangmin Xu; Bruce P Lee
Journal:  Biomacromolecules       Date:  2010-10-04       Impact factor: 6.988

5.  Bacterial clearance of biologic grafts used in hernia repair: an experimental study.

Authors:  K C Harth; A-M Broome; M R Jacobs; J A Blatnik; F Zeinali; S Bajaksouzian; M J Rosen
Journal:  Surg Endosc       Date:  2011-02-07       Impact factor: 4.584

6.  Human vital amniotic membrane reduces adhesions in experimental intraperitoneal onlay mesh repair.

Authors:  A H Petter-Puchner; R H Fortelny; K Mika; S Hennerbichler; H Redl; C Gabriel
Journal:  Surg Endosc       Date:  2010-12-10       Impact factor: 4.584

7.  Postimplant intraperitoneal behavior of collagen-based meshes followed by laparoscopy.

Authors:  Juan M Bellón; Marta Rodríguez; Verónica Gómez-Gil; Sandra Sotomayor; Julia Buján; Gemma Pascual
Journal:  Surg Endosc       Date:  2011-07-26       Impact factor: 4.584

8.  Prosthetic abdominal wall hernia repair in emergency surgery: from polypropylene to biological meshes.

Authors:  G Campanelli; F Catena; L Ansaloni
Journal:  World J Emerg Surg       Date:  2008-12-04       Impact factor: 5.469

Review 9.  Biomaterials for pelvic floor reconstructive surgery: how can we do better?

Authors:  Giulia Gigliobianco; Sabiniano Roman Regueros; Nadir I Osman; Julio Bissoli; Anthony J Bullock; Chris R Chapple; Sheila MacNeil
Journal:  Biomed Res Int       Date:  2015-04-21       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.