Literature DB >> 17949059

Photoresist with low fluorescence for bioanalytical applications.

Jeng-Hao Pai1, Yuli Wang, Gina To'A Salazar, Christopher E Sims, Mark Bachman, G P Li, Nancy L Allbritton.   

Abstract

The negative photoresist SU-8 has found widespread use as a material in the fabrication of microelectrical-mechanical systems (MEMS). Although SU-8 has been utilized as a structural material for biological MEMS, a number of SU-8 properties limit its application in these bioanalytical devices. These attributes include its brittleness, nonspecific adsorption of biomolecules, and high fluorescence in the visible wavelengths. In addition, native SU-8 is a poor substrate for cellular adhesion. Photoresists composed of resins with epoxide side groups and photoacids were screened for their ability to serve as a low-fluorescence photoresist with sufficient resolution to generate microstructures with dimensions of 5-10 microm. The fluorescence of structures formed from 1002F photoresist (1002F resin combined with triarylsulfonium hexafluoroantimonate salts) was as much as 10 times less fluorescent than similar SU-8 microstructures. The absorbance of 1002F in the visible wavelengths was also substantially lower than that of SU-8. Microstructures or pallets with an aspect ratio as high as 4:1 could be formed permitting 1002F to be used as a structural material in the fabrication of arrays of pallets for sorting adherent cells. Several different cell types were able to adhere to native 1002F surfaces, and the viability of these cells was excellent. As with SU-8, 1002F has a weak adhesion to glass, a favorable attribute when the pallet arrays are used to sort adherent cells. A threshold, laser pulse energy of 3.5 microJ was required to release individual 50 microm, 1002F pallets from an array. Relative to SU-8, 1002F photoresist offers substantial improvements as a substrate in bioanalytical devices and is likely to find widespread use in BioMEMS.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17949059      PMCID: PMC2435225          DOI: 10.1021/ac071528q

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  12 in total

1.  Analysis of single-cell differences by use of an on-chip microculture system and optical trapping.

Authors:  Y Wakamoto; I Inoue; H Moriguchi; K Yasuda
Journal:  Fresenius J Anal Chem       Date:  2001-09

Review 2.  Soft lithography in biology and biochemistry.

Authors:  G M Whitesides; E Ostuni; S Takayama; X Jiang; D E Ingber
Journal:  Annu Rev Biomed Eng       Date:  2001       Impact factor: 9.590

3.  Biocompatibility and biofouling of MEMS drug delivery devices.

Authors:  Gabriela Voskerician; Matthew S Shive; Rebecca S Shawgo; Horst von Recum; James M Anderson; Michael J Cima; Robert Langer
Journal:  Biomaterials       Date:  2003-05       Impact factor: 12.479

4.  Evaluation of MEMS materials of construction for implantable medical devices.

Authors:  Geoffrey Kotzar; Mark Freas; Phillip Abel; Aaron Fleischman; Shuvo Roy; Christian Zorman; James M Moran; Jeff Melzak
Journal:  Biomaterials       Date:  2002-07       Impact factor: 12.479

5.  Immobilisation of DNA to polymerised SU-8 photoresist.

Authors:  Rodolphe Marie; Silvan Schmid; Alicia Johansson; Louise Ejsing; Maria Nordström; Daniel Häfliger; Claus Bv Christensen; Anja Boisen; Martin Dufva
Journal:  Biosens Bioelectron       Date:  2006-01-15       Impact factor: 10.618

6.  Micropatterning of living cells on a heterogeneously wetted surface.

Authors:  Yuli Wang; Christopher E Sims; Paul Marc; Mark Bachman; G P Li; Nancy L Allbritton
Journal:  Langmuir       Date:  2006-09-12       Impact factor: 3.882

7.  Micropallet arrays for the separation of single, adherent cells.

Authors:  Georgina To'a Salazar; Yuli Wang; Grace Young; Mark Bachman; Christopher E Sims; G P Li; Nancy L Allbritton
Journal:  Anal Chem       Date:  2007-01-15       Impact factor: 6.986

8.  Broadening cell selection criteria with micropallet arrays of adherent cells.

Authors:  Yuli Wang; Grace Young; Phillip C Aoto; Jeng-Hao Pai; Mark Bachman; G P Li; Christopher E Sims; Nancy L Allbritton
Journal:  Cytometry A       Date:  2007-10       Impact factor: 4.355

Review 9.  Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low-density polyethylene and polydimethylsiloxane: a review.

Authors:  M C Bélanger; Y Marois
Journal:  J Biomed Mater Res       Date:  2001

10.  Simple photografting method to chemically modify and micropattern the surface of SU-8 photoresist.

Authors:  Yuli Wang; Mark Bachman; Christopher E Sims; G P Li; Nancy L Allbritton
Journal:  Langmuir       Date:  2006-03-14       Impact factor: 3.882

View more
  53 in total

1.  Impact of release dynamics of laser-irradiated polymer micropallets on the viability of selected adherent cells.

Authors:  Huan Ma; Wael Mismar; Yuli Wang; Donald W Small; Mat Ras; Nancy L Allbritton; Christopher E Sims; Vasan Venugopalan
Journal:  J R Soc Interface       Date:  2011-12-07       Impact factor: 4.118

2.  In situ roughening of polymeric microstructures.

Authors:  Hamed Shadpour; Nancy L Allbritton
Journal:  ACS Appl Mater Interfaces       Date:  2010-04       Impact factor: 9.229

3.  Microdevice to capture colon crypts for in vitro studies.

Authors:  Yuli Wang; Rahul Dhopeshwarkar; Rani Najdi; Marian L Waterman; Christopher E Sims; Nancy Allbritton
Journal:  Lab Chip       Date:  2010-04-07       Impact factor: 6.799

4.  Microtable arrays for culture and isolation of cell colonies.

Authors:  Jeng-Hao Pai; Wei Xu; Christopher E Sims; Nancy L Allbritton
Journal:  Anal Bioanal Chem       Date:  2010-07-20       Impact factor: 4.142

5.  Fabrication and biological evaluation of uniform extracellular matrix coatings on discontinuous photolithography generated micropallet arrays.

Authors:  Nicholas M Gunn; Mark Bachman; Guann-Pyng Li; Edward L Nelson
Journal:  J Biomed Mater Res A       Date:  2010-11       Impact factor: 4.396

6.  Use of a virtual wall valve in polydimethylsiloxane microfluidic devices for bioanalytical applications.

Authors:  Hsuan-Hong Lai; Wei Xu; Nancy L Allbritton
Journal:  Biomicrofluidics       Date:  2011-05-05       Impact factor: 2.800

7.  Patterning pallet arrays for cell selection based on high-resolution measurements of fluorescent biosensors.

Authors:  Hamed Shadpour; Jon S Zawistowski; Annadele Herman; Klaus Hahn; Nancy L Allbritton
Journal:  Anal Chim Acta       Date:  2011-04-16       Impact factor: 6.558

8.  Development of low-fluorescence thick photoresist for high-aspect-ratio microstructure in bio-application.

Authors:  H Tamai; K Maruo; H Ueno; K Terao; H Kotera; T Suzuki
Journal:  Biomicrofluidics       Date:  2015-04-13       Impact factor: 2.800

9.  Laser-based directed release of array elements for efficient collection into targeted microwells.

Authors:  Nicholas C Dobes; Rahul Dhopeshwarkar; W Hampton Henley; J Michael Ramsey; Christopher E Sims; Nancy L Allbritton
Journal:  Analyst       Date:  2012-12-05       Impact factor: 4.616

10.  Automated capillary electrophoresis system for fast single-cell analysis.

Authors:  Alexandra J Dickinson; Paul M Armistead; Nancy L Allbritton
Journal:  Anal Chem       Date:  2013-04-09       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.