Literature DB >> 17947823

Dysphotopsia after cataract surgery: comparison of four different intraocular lenses.

P Bournas1, S Drazinos, D Kanellas, M Arvanitis, E Vaikoussis.   

Abstract

AIM: To assess the risk of dysphotopsia after phacoemulsification, with the use of four different intraocular lens (IOL) models.
METHODS: In this prospective randomized study, 600 patients underwent phacoemulsification surgery. Four study groups were formed, according to the type of the IOL implanted: Meridian HP60M [Bausch & Lomb, hydrogel, 6 mm, three piece (3P), square edge, refraction index (RI): 1.470], Acrysof MA60BM (Alcon, acrylic, 6 mm, 3P, square edge, RI: 1.550), Acrysof MA30BA (Alcon, acrylic, 5.5 mm, 3P, square edge, RI: 1.550) and Clariflex (AMO, silicone, 6 mm, 3P, anterior round and posterior square edge, RI: 1.460). Patients were examined for dysphotopsia symptoms after 1 week, 1, 3 and 6 months.
RESULTS: During the first follow-up visit, 117 patients (19.5%) reported dysphotopsia. During the next visits, the actual number of patients still reporting phenomena declined. Optic phenomena occurred less frequently in patients with AMO Clariflex lens, especially when compared to Acrysof (5.5 and 6 mm); IOL odds ratios ranged from 2.27 to 6.7, depending on follow-up time (p value < 0.05). IOL optic diameter was negatively but significantly associated with the risk of dysphotopsia.
CONCLUSIONS: The design of the optic edge and the optic diameter of the IOL play an important role in the occurrence of dysphotopsia. AMO Clariflex, with round anterior and square posterior edge, overcomes the problem of dysphotopsia to a considerable extent. (c) 2007 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2007        PMID: 17947823     DOI: 10.1159/000107496

Source DB:  PubMed          Journal:  Ophthalmologica        ISSN: 0030-3755            Impact factor:   3.250


  3 in total

1.  Efficacy of Large Optic Intraocular Lenses in Myopic Eyes with Posterior Segment Pathology.

Authors:  Andreas F Borkenstein; Eva-Maria Borkenstein
Journal:  Ophthalmol Ther       Date:  2021-11-27

2.  Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens.

Authors:  Ya-Wen Guo; Jun Li; Hui Song; Xin Tang
Journal:  J Ophthalmol       Date:  2014-03-03       Impact factor: 1.909

Review 3.  Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.

Authors:  Zahra Ashena; Sundas Maqsood; Syed Naqib Ahmed; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2020-09-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.