Literature DB >> 17946678

Continuous blood pressure monitoring using ECG and finger photoplethysmogram.

C P Chua1, C Heneghan.   

Abstract

Pulse arrival time and the amplitude of the finger photoplethysmogram were used to track blood pressure continuously over 10-minute intervals. The measures were recorded with a holter-oximeter from a sample of 8 young, healthy human subjects in the supine and standing positions. Results indicate that, with individual calibration, systolic and diastolic blood pressure can be estimated with an average error of +/-6 and +/-4 mmHg respectively. Using pulse arrival time in combination with the amplitude of the finger photoplethysmogram gave better results than using any one alone, with PPG amplitude appearing to be more robust.

Entities:  

Mesh:

Year:  2006        PMID: 17946678     DOI: 10.1109/IEMBS.2006.259612

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  9 in total

1.  A Comparison of Deep Learning Techniques for Arterial Blood Pressure Prediction.

Authors:  Annunziata Paviglianiti; Vincenzo Randazzo; Stefano Villata; Giansalvo Cirrincione; Eros Pasero
Journal:  Cognit Comput       Date:  2021-08-27       Impact factor: 4.890

2.  Noninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations.

Authors:  Md Kamrul Hasan; Md Hasanul Aziz; Md Ishrak Islam Zarif; Mahmudul Hasan; Mma Hashem; Shion Guha; Richard R Love; Sheikh Ahamed
Journal:  JMIR Mhealth Uhealth       Date:  2021-04-08       Impact factor: 4.773

3.  Sleep Deprivation Deteriorates Heart Rate Variability and Photoplethysmography.

Authors:  Nicolas Bourdillon; Fanny Jeanneret; Masih Nilchian; Patrick Albertoni; Pascal Ha; Grégoire P Millet
Journal:  Front Neurosci       Date:  2021-04-08       Impact factor: 4.677

Review 4.  Photoplethysmogram Analysis and Applications: An Integrative Review.

Authors:  Junyung Park; Hyeon Seok Seok; Sang-Su Kim; Hangsik Shin
Journal:  Front Physiol       Date:  2022-03-01       Impact factor: 4.566

Review 5.  On the analysis of fingertip photoplethysmogram signals.

Authors:  Mohamed Elgendi
Journal:  Curr Cardiol Rev       Date:  2012-02

6.  Arteries Stiffen With Age, but Can Retain an Ability to Become More Elastic With Applied External Cuff Pressure.

Authors:  Chengyu Liu; Dingchang Zheng; Alan Murray
Journal:  Medicine (Baltimore)       Date:  2015-10       Impact factor: 1.817

7.  RheoStim: Development of an Adaptive Multi-Sensor to Prevent Venous Stasis.

Authors:  Sören Weyer; Fabio Weishaupt; Christian Kleeberg; Steffen Leonhardt; Daniel Teichmann
Journal:  Sensors (Basel)       Date:  2016-03-24       Impact factor: 3.576

8.  Cuffless blood pressure estimation using only a smartphone.

Authors:  Kenta Matsumura; Peter Rolfe; Sogo Toda; Takehiro Yamakoshi
Journal:  Sci Rep       Date:  2018-05-08       Impact factor: 4.379

9.  Innovative Multi-Site Photoplethysmography Analysis for Quantifying Pulse Amplitude and Timing Variability Characteristics in Peripheral Arterial Disease.

Authors:  Michael Bentham; Gerard Stansby; John Allen
Journal:  Diseases       Date:  2018-09-17
  9 in total