Literature DB >> 17946132

Control of a pneumatic orthosis for upper extremity stroke rehabilitation.

Eric T Wolbrecht1, John Leavitt, David J Reinkensmeyer, James E Bobrow.   

Abstract

A key challenge in rehabilitation robotics is the development of a lightweight, large force, high degrees-of-freedom device that can assist in functional rehabilitation of the arm. Pneumatic actuators can potentially help meet this challenge because of their high power-to-weight ratio. They are currently not widely used for rehabilitation robotics because they are difficult to control. This paper describes the control development of a pneumatically actuated, upper extremity orthosis for rehabilitation after stroke. To provide the sensing needed for good pneumatic control, position and velocity of the robot are estimated by a unique implementation of a Kalman filter using MEMS accelerometers. To compensate for the nonlinear behavior of the pneumatic servovalves, force control is achieved using a new method for air flow mapping using experimentally measured data in a least-squares regression. To help patients move with an inherently compliant robot, a high level controller that assists only as needed in reaching exercises is developed. This high level controller differs from traditional trajectory-based, position controllers, allowing free voluntary movements toward a target while resisting movements away from the target. When the target cannot be reached voluntarily, the controller slowly builds up force, pushing the arm toward the target. As each target position is reached, the controller builds an internal model of the subject's capability, learning the forces necessary to complete movements. Preliminary testing performed on a non-disabled subject demonstrated the ability of the orthosis to complete reaching movements with graded assistance and to adapt to the effort level of the subject. Thus, the orthosis is a promising tool for upper extremity rehabilitation after stroke.

Entities:  

Mesh:

Year:  2006        PMID: 17946132     DOI: 10.1109/IEMBS.2006.259941

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

Review 1.  Pneumatic robotic systems for upper limb rehabilitation.

Authors:  Ricardo Morales; Francisco Javier Badesa; Nicolás García-Aracil; José María Sabater; Carlos Pérez-Vidal
Journal:  Med Biol Eng Comput       Date:  2011-08-06       Impact factor: 2.602

Review 2.  A survey on robotic devices for upper limb rehabilitation.

Authors:  Paweł Maciejasz; Jörg Eschweiler; Kurt Gerlach-Hahn; Arne Jansen-Troy; Steffen Leonhardt
Journal:  J Neuroeng Rehabil       Date:  2014-01-09       Impact factor: 4.262

3.  Optimization of the ASPIRE Spherical Parallel Rehabilitation Robot Based on Its Clinical Evaluation.

Authors:  Paul Tucan; Calin Vaida; Ionut Ulinici; Alexandru Banica; Alin Burz; Nicoleta Pop; Iosif Birlescu; Bogdan Gherman; Nicolae Plitea; Tiberiu Antal; Giuseppe Carbone; Doina Pisla
Journal:  Int J Environ Res Public Health       Date:  2021-03-22       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.