Literature DB >> 17946020

Unsupervised segmentation of cardiac PET transmission images for automatic heart volume extraction.

Anu Juslin1, Jussi Tohka.   

Abstract

In this study, we propose an automatic method to extract the heart volume from the cardiac positron emission tomography (PET) transmission images. The method combines the automatic 3D segmentation of the transmission image using Markov random fields (MRFs) to surface extraction using deformable models. Deformable models were automatically initialized using the MRFs segmentation result. The extraction of the heart region is needed e.g. in independent component analysis (ICA). The volume of the heart can be used to mask the emission image corresponding to the transmission image, so that only the cardiac region is used for the analysis. The masking restricts the number of independent components and reduces the computation time. In addition, the MRF segmentation result could be used for attenuation correction. The method was tested with 25 patient images. The MRF segmentation results were of good quality in all cases and we were able to extract the heart volume from all the images.

Entities:  

Mesh:

Year:  2006        PMID: 17946020     DOI: 10.1109/IEMBS.2006.259416

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Oriented Markov random field based dendritic spine segmentation for fluorescence microscopy images.

Authors:  Jie Cheng; Xiaobo Zhou; Eric L Miller; Veronica A Alvarez; Bernardo L Sabatini; Stephen T C Wong
Journal:  Neuroinformatics       Date:  2010-10

2.  Alignment of 3-dimensional cardiac structures in O-15-labeled water PET emission images with mutual information.

Authors:  Anu Juslin; Jyrki Lötjönen; Sergey V Nesterov; Kari Kalliokoski; Juhani Knuuti; Ulla Ruotsalainen
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

3.  3D Segmentation Algorithms for Computerized Tomographic Imaging: a Systematic Literature Review.

Authors:  L E Carvalho; A C Sobieranski; A von Wangenheim
Journal:  J Digit Imaging       Date:  2018-12       Impact factor: 4.056

4.  Image-derived input function derived from a supervised clustering algorithm: methodology and validation in a clinical protocol using [11C](R)-rolipram.

Authors:  Chul Hyoung Lyoo; Paolo Zanotti-Fregonara; Sami S Zoghbi; Jeih-San Liow; Rong Xu; Victor W Pike; Carlos A Zarate; Masahiro Fujita; Robert B Innis
Journal:  PLoS One       Date:  2014-02-20       Impact factor: 3.240

5.  An image processing tool for the detection of anthracycline-induced cardiotoxicity by evaluating the myocardial metabolic activity in [18F]FDG PET/CT.

Authors:  Alexander P Seiffert; Adolfo Gómez-Grande; Gonzalo Castro-Leal; Antonia Rodríguez; David Palomino-Fernández; Enrique J Gómez; Patricia Sánchez-González; Héctor Bueno
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-10-26       Impact factor: 2.924

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.