Literature DB >> 17946006

Wearable, cuff-less PPG-based blood pressure monitor with novel height sensor.

Phillip A Shaltis1, Andrew Reisner, H Harry Asada.   

Abstract

A truly wearable non-invasive blood pressure (NIBP) sensor--light-weight, compact, unobstrusive, and essentially unnoticeable to the patient--could revolutionize healthcare delivered beyond the traditional walls of medical facilities, offering new ways to care for patients in their everyday surroundings. This paper presents results from our work towards the development of a self-contained, wearable blood pressure sensor. A PPG-based approach to blood pressure monitoring is presented. The design enables significant miniaturization of traditional oscillometric devices without the need for occlusive circumferential pressures. It will be shown how natural raising and lowering of the arm replaces the need for bulky actuators. Additionally, a dual-accelerometer height sensor that is tetherless is proposed and supported by experimental results.

Entities:  

Mesh:

Year:  2006        PMID: 17946006     DOI: 10.1109/IEMBS.2006.260027

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  6 in total

Review 1.  A review of wearable sensors and systems with application in rehabilitation.

Authors:  Shyamal Patel; Hyung Park; Paolo Bonato; Leighton Chan; Mary Rodgers
Journal:  J Neuroeng Rehabil       Date:  2012-04-20       Impact factor: 4.262

Review 2.  Detecting vital signs with wearable wireless sensors.

Authors:  Tuba Yilmaz; Robert Foster; Yang Hao
Journal:  Sensors (Basel)       Date:  2010-12-02       Impact factor: 3.576

Review 3.  The Effectiveness of Lower-Limb Wearable Technology for Improving Activity and Participation in Adult Stroke Survivors: A Systematic Review.

Authors:  Lauren Powell; Jack Parker; Marrissa Martyn St-James; Susan Mawson
Journal:  J Med Internet Res       Date:  2016-10-07       Impact factor: 5.428

4.  Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study.

Authors:  Hangsik Shin; Se Dong Min
Journal:  Biomed Eng Online       Date:  2017-01-10       Impact factor: 2.819

Review 5.  Effectiveness of Upper Limb Wearable Technology for Improving Activity and Participation in Adult Stroke Survivors: Systematic Review.

Authors:  Jack Parker; Lauren Powell; Susan Mawson
Journal:  J Med Internet Res       Date:  2020-01-08       Impact factor: 5.428

6.  Capacitive Heart-Rate Sensing on Touch Screen Panel with Laterally Interspaced Electrodes.

Authors:  Junhyung Kim; Wonho Song; Sungchul Jung; Yuna Kim; Wonsang Park; Bonghyun You; Kibog Park
Journal:  Sensors (Basel)       Date:  2020-07-17       Impact factor: 3.576

  6 in total