Literature DB >> 17945641

Maternal ECG removal from non-invasive fetal ECG recordings.

R Vullings1, C Peters, M Mischi, G Oei, J Bergmans.   

Abstract

Fetal monitoring during pregnancy is important to support medical decision making. The fetal electrocardiogram (fECG) is a valuable signal to diagnose fetal well-being. Non-invasive recording of the fECG is performed by positioning electrodes on the maternal abdomen. The signal-to-noise ratio of these recordings is relatively low and the main undesired signal is the maternal electrocardiogram (mECG). Existing methods to remove the mECG signal are not sufficiently accurate to extract the complete fECG signal. In this paper, a novel method for removal of the mECG signal from abdominal recordings is presented. It is an extension of the linear prediction method. Each mECG complex is segmented and these segments are separately estimated by linear prediction. Both the presented method and the standard linear prediction are applied to simulated abdominal recordings and evaluated by determining the rms errors between the estimated and the actual fECG signals. The ratio between the rms errors of the linear prediction method and the presented method varies between 0.4 dB and 2.3 dB. It can therefore be concluded that the presented method is capable of a more accurate removal of the mECG signal for all simulated abdominal recordings with respect to the linear prediction method.

Entities:  

Mesh:

Year:  2006        PMID: 17945641     DOI: 10.1109/IEMBS.2006.259675

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

Review 1.  Noninvasive fetal electrocardiography: an overview of the signal electrophysiological meaning, recording procedures, and processing techniques.

Authors:  Angela Agostinelli; Marla Grillo; Alessandra Biagini; Corrado Giuliani; Luca Burattini; Sandro Fioretti; Francesco Di Nardo; Stefano R Giannubilo; Andrea Ciavattini; Laura Burattini
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-02-02       Impact factor: 1.468

2.  An adaptive integrated algorithm for noninvasive fetal ECG separation and noise reduction based on ICA-EEMD-WS.

Authors:  Guangchen Liu; Yihui Luan
Journal:  Med Biol Eng Comput       Date:  2015-10-01       Impact factor: 2.602

3.  Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy.

Authors:  Istvan Peterfi; Lorand Kellenyi; Andras Szilagyi
Journal:  Obstet Gynecol Int       Date:  2014-10-08

4.  A non-invasive multimodal foetal ECG-Doppler dataset for antenatal cardiology research.

Authors:  Eleonora Sulas; Monica Urru; Roberto Tumbarello; Luigi Raffo; Reza Sameni; Danilo Pani
Journal:  Sci Data       Date:  2021-01-26       Impact factor: 6.444

  4 in total