Literature DB >> 17945573

MRI alone simulation for conformal radiation therapy of prostate cancer: technical aspects.

D Pasquier1, N Betrouni, M Vermandel, T Lacornerie, E Lartigau, J Rousseau.   

Abstract

The value of MRI in defining target volumes and organs at risk is established. Numerous difficulties appear to stand in the way of using MRI alone in dose planning, with the result that this imaging modality is used in most cases in conjunction with computerized X-ray tomography (CT). The aim of this paper is to appreciate these difficulties: geometrical distortion, chemical shifts, dosimetric accuracy. Geometrical distortion measurements were carried out on two 1.5 T MR scanners and the effect of chemical shift and magnetic susceptibility were evaluated in volunteers. The effect on dosimetric calculations of uncertainty in determining electron densities was evaluated too. Geometrical distortion remained at small values: less than 2 mm and 3 mm for field of view of 20 cm and 45 cm. The chemical shift and magnetic susceptibility values obtained, ranging from 0.3 to 3 mm, were well below the theoretical values. The assignment of relative electron densities to only two structures in MR images seems to permit dose planning that is identical with that obtained with CT. None of the technical obstacles mentioned represents a stumbling block. The access to MRI facility could represent a persisting problem.

Entities:  

Mesh:

Year:  2006        PMID: 17945573     DOI: 10.1109/IEMBS.2006.260341

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions.

Authors:  Joakim H Jonsson; Magnus G Karlsson; Mikael Karlsson; Tufve Nyholm
Journal:  Radiat Oncol       Date:  2010-06-30       Impact factor: 3.481

2.  Synthetic CT for MRI-based liver stereotactic body radiotherapy treatment planning.

Authors:  Jeremy S Bredfeldt; Lianli Liu; Mary Feng; Yue Cao; James M Balter
Journal:  Phys Med Biol       Date:  2017-03-17       Impact factor: 3.609

Review 3.  MRI-only treatment planning: benefits and challenges.

Authors:  Amir M Owrangi; Peter B Greer; Carri K Glide-Hurst
Journal:  Phys Med Biol       Date:  2018-02-26       Impact factor: 3.609

4.  Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments.

Authors:  Tufve Nyholm; Morgan Nyberg; Magnus G Karlsson; Mikael Karlsson
Journal:  Radiat Oncol       Date:  2009-11-17       Impact factor: 3.481

  4 in total