Literature DB >> 17944635

An outcome study on complications using routine ultrasound assistance for internal jugular vein cannulation.

M Lamperti1, P Cortellazzi, G D'Onofrio, M Subert, C Falcone, G Filippini, D Caldiroli.   

Abstract

BACKGROUND: Ultrasound guidance for central venous cannulation is advised by recent guidelines, but is not being applied in everyday practice. The purpose of this study was to determine the reduction in complications when applying an ultrasound locating device for internal jugular vein catheterization.
METHODS: An observational study was conducted from November 2004 to October 2005 in a tertiary neurosurgical hospital on 300 patients undergoing internal jugular vein cannulation using an ultrasound technique. Patients were not randomized and operators were trained using theoretical and practical courses. Prior to the study, the investigators, who were consultant anaesthesiologists, had to perform at least 20 successful supervised cannulations.
RESULTS: Cannulation was successful in all cases. The incidence of arterial puncture was 2.7%, and multiple venous punctures represented the main minor complication (14%). Bivariate analysis of the overall complications revealed no significant correlation with age group, American Society of Anesthesiologists' (ASA) classification, body mass index, or position and diameter of the vein.
CONCLUSIONS: Ultrasound cannulation of the internal jugular vein minimized complications. These could be avoided when new ultrasound probes and specific needles are introduced.

Entities:  

Mesh:

Year:  2007        PMID: 17944635     DOI: 10.1111/j.1399-6576.2007.01442.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  4 in total

1.  Evaluation of vascular puncture needles with specific modifications for enhanced ultrasound visibility: In vitro study.

Authors:  Nobuyuki Kawai; Hiroki Minamiguchi; Morio Sato; Motoki Nakai; Hiroki Sanda; Takami Tanaka; Akira Ikoma; Kouhei Nakata; Shintaro Shirai; Tetsuo Sonomura
Journal:  World J Radiol       Date:  2012-06-28

2.  Non-selective beta-adrenergic blockade prevents reduction of the cerebral metabolic ratio during exhaustive exercise in humans.

Authors:  Thomas Seifert Larsen; Peter Rasmussen; Morten Overgaard; Niels H Secher; Henning B Nielsen
Journal:  J Physiol       Date:  2008-04-10       Impact factor: 5.182

3.  Changes in the relationship between the right internal jugular vein and an anatomical landmark after head rotation.

Authors:  Sun Young Park; Min Jung Kim; Mun Gyu Kim; Se Jin Lee; Sang Ho Kim; Si Young Ok; Soon Im Kim
Journal:  Korean J Anesthesiol       Date:  2011-08-23

4.  Central Venous Cannulation of the Internal Jugular Vein Using Ultrasound-Guided and Anatomical Landmark Techniques.

Authors:  Mehdi Fathi; Azra Izanloo; Saeed Jahanbakhsh; Mehryar Taghavi Gilani; Ali Majidzadeh; Azam Sabri Benhangi; Naser Paravi
Journal:  Anesth Pain Med       Date:  2016-05-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.