Literature DB >> 17943264

[Image postprocessing of aortic CTA and MRA].

H von Tengg-Kobligk1, T F Weber, F Rengier, D Böckler, H Schumacher, H-U Kauczor.   

Abstract

Multiplanar reformation (MPR) is the most relevant tool for patient selection and precise procedural planning and also for analyzing postinterventional complications. Curved MPR is used primarily for semiautomated or completely automated calculation of the centerline of the vascular lumen and to estimate the orthogonal vessel diameter and longitudinal extent. Reproducible and accurate measurement of complex pathologies and courses of vessels extends the range of diagnostic radiology. Contemporary scanner consoles allow automated processing of maximum intensity projections (MIP) and standard MPR and their storage in PACS. To improve patient selection, procedural planning, root-cause analysis postoperatively for assessment of treatment effects and to make better communication of findings to nonradiologists possible, volume rendering techniques (VRT) are a beneficial adjunct to source images. With current algorithms semiautomated segmentation is satisfactory for vessels and bones, but not for low-contrast structures (soft tissues), which still need to be segmented manually. In general, isotropic CT source data are preferable to MR images, which are often anisotropic. In many European countries image postprocessing is still not adequately reimbursed although the doctors making referrals often specifically and emphatically demand 3D visualization and measurements in daily practice.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17943264     DOI: 10.1007/s00117-007-1583-8

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  33 in total

1.  Three-dimensional volume rendering of spiral CT data: theory and method.

Authors:  P S Calhoun; B S Kuszyk; D G Heath; J C Carley; E K Fishman
Journal:  Radiographics       Date:  1999 May-Jun       Impact factor: 5.333

2.  Images in vascular medicine. Postprocessing 'fly-through' of multislice computed tomography after thoracic endografting.

Authors:  Dittmar Böckler; Jens-Rainer Allenberg; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Vasc Med       Date:  2005-02       Impact factor: 3.239

3.  Standardized volume rendering for magnetic resonance angiography measurements in the abdominal aorta.

Authors:  A Persson; T B Brismar; C Lundström; N Dahlström; F Othberg; O Smedby
Journal:  Acta Radiol       Date:  2006-03       Impact factor: 1.990

4.  Interactive real-time multiplanar CT imaging.

Authors:  D R Ney; E K Fishman; D Magid; J E Kuhlman
Journal:  Radiology       Date:  1989-01       Impact factor: 11.105

5.  Comparison of projection algorithms used for the construction of maximum intensity projection images.

Authors:  S Schreiner; C B Paschal; R L Galloway
Journal:  J Comput Assist Tomogr       Date:  1996 Jan-Feb       Impact factor: 1.826

Review 6.  Current status of three-dimensional spiral CT scanning for imaging the vasculature.

Authors:  G D Rubin; M D Dake; C P Semba
Journal:  Radiol Clin North Am       Date:  1995-01       Impact factor: 2.303

7.  STS-MIP: a new reconstruction technique for CT of the chest.

Authors:  S Napel; G D Rubin; R B Jeffrey
Journal:  J Comput Assist Tomogr       Date:  1993 Sep-Oct       Impact factor: 1.826

8.  MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses.

Authors:  Juan R Ayuso; Teresa M de Caralt; Mario Pages; Vicente Riambau; Carmen Ayuso; Marcelo Sanchez; María I Real; Xavier Montaña
Journal:  J Magn Reson Imaging       Date:  2004-11       Impact factor: 4.813

9.  [Software-assisted CT-postprocessing of the carotid arteries].

Authors:  A Gerhards; P Raab; S Herber; K-F Kreitner; T Boskamp; P Mildenberger
Journal:  Rofo       Date:  2004-06

10.  Diagnostic accuracy of image postprocessing methods for the detection of coronary artery stenoses by using multidetector CT.

Authors:  Maros Ferencik; Dieter Ropers; Suhny Abbara; Ricardo C Cury; Udo Hoffmann; Koen Nieman; Thomas J Brady; Fabian Moselewski; Werner G Daniel; Stephan Achenbach
Journal:  Radiology       Date:  2007-06       Impact factor: 11.105

View more
  2 in total

1.  The Endurant Stent Graft System: 15-month follow-up report in patients with challenging abdominal aortic anatomies.

Authors:  Alexander Hyhlik-Dürr; Tim F Weber; Drossos Kotelis; Fabian Rengier; Johannes Gahlen; Stefanie Böck; Jürgen Köhler; Christoph-M Ratusinski; Dittmar Böckler
Journal:  Langenbecks Arch Surg       Date:  2011-05-25       Impact factor: 3.445

2.  [Endovascular aortic surgery: management of secondary aortobronchial and aorto-enteral fistulas].

Authors:  A Hyhlik-Dürr; P Geisbüsch; M Hakimi; T F Weber; A Schaible; D Böckler
Journal:  Chirurg       Date:  2009-10       Impact factor: 0.955

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.