Doppler mode pulse sequences mitigate glomerular capillary hemorrhage in contrast-aided diagnostic ultrasound of rat kidney.

Douglas L Miller1, Chunyan Dou, Roger C Wiggins.   

Abstract

Glomerular capillary hemorrhage (GCH) induced in rat kidney by diagnostic ultrasound involving contrast agent destruction was characterized for different modes to explore possible mitigation strategies. Anesthetized hairless rats were scanned at 2.5 MHz in a water bath with contrast agent infused at 10 microl/kg/minute via tail vein. B mode flash echo imaging (FEI), color Doppler (CD) FEI and realtime Doppler imaging at 1 frame per second were tested, which had image pulse sequences of approximately 0.53 ms, 15.8 ms, and 83.5 ms duration, respectively. Bioeffects endpoints included grossly observed blood-filled tubules, histological evaluation of GCH, and detection of hematuria. B mode FEI for 1 minute induced GCH in 38.6+/-17.1% of glomeruli in histology from the scan plane for a peak rarefactional pressure amplitude (RPA) of 2.6 MPa. The threshold for GCH was approximately 1.5 MPa, confirmed by 10-minute exposure with agent infusion. Paradoxically, CD mode FEI delivered many more pulses but produced less GCH (P < 0.02), and real-time Doppler mode induced only 5.3 +/- 3.8% (P < 0.005). Hematuria results followed the GCH trends. These findings indicate a promising strategy, which is to use relatively slow ramp-up of pulse RPAs in agent-destroying image pulse sequences, for mitigating potential bioeffects in contrastaided diagnostic ultrasound.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17941386     DOI: 10.1109/tuffc.2007.464

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  4 in total

1.  Combining functional imaging and interstitial pressure measurements to evaluate two anti-angiogenic treatments.

Authors:  Ingrid Leguerney; Nathalie Lassau; Serge Koscielny; Mélanie Rodrigues; Christophe Massard; Valérie Rouffiac; Baya Benatsou; Jessie Thalmensi; Olivia Bawa; Paule Opolon; Pierre Peronneau; Alain Roche
Journal:  Invest New Drugs       Date:  2010-10-06       Impact factor: 3.850

2.  Contrast-enhanced diagnostic ultrasound causes renal tissue damage in a porcine model.

Authors:  Douglas L Miller; Chunyan Dou; Roger C Wiggins
Journal:  J Ultrasound Med       Date:  2010-10       Impact factor: 2.153

3.  Frequency dependence of kidney injury induced by contrast-aided diagnostic ultrasound in rats.

Authors:  Douglas L Miller; Chunyan Dou; Roger C Wiggins
Journal:  Ultrasound Med Biol       Date:  2008-05-15       Impact factor: 2.998

4.  In vivo gas body efficacy for glomerular capillary hemorrhage induced by diagnostic ultrasound in rats.

Authors:  Douglas L Miller; Chunyan Dou; Roger C Wiggins
Journal:  IEEE Trans Biomed Eng       Date:  2009-08-25       Impact factor: 4.538

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.