Broadband PVDF membrane hydrophone for comparisons of hydrophone calibration methods up to 140 MHz.

Volker Wilkens1, Walter Molkenstruck.   

Abstract

A PVDF membrane hydrophone has been constructed in particular for comparisons of broadband ultrasound hydrophone calibration methods and of the results obtained by different laboratories. Intercomparisons have to accompany the efforts currently undertaken to enhance the calibration frequency ranges and to implement the extension from the determination of amplitude-only to complex-valued calibration data. It can be expected that such hydrophone data will be used much more frequently in the future for exposure measurements on medical ultrasound equipment, in particular for the detection of nonlinearly distorted waveforms. The hydrophone design chosen has a foil thickness of 9 microm and an electrode diameter of 210 microm. A broadband differential preamplifier (-3 dB roll-off frequency: 95 MHz) is integrated to achieve a high signal-to-noise ratio over a broad frequency range (e.g., 26 dB-30 dB in the range 50 MHz to 140 MHz for measurements of nonlinearly distorted pulses). The hydrophone response was characterized by means of a primary interferometric calibration technique, by substitution calibration using time-delay spectrometry, and by complex broadband pulse calibration using nonlinear sound propagation. The results show a flat frequency response up to 40 MHz (maximum variations below +/-0.6 dB) and a thickness mode resonance at about 105 MHz. They indicate a useable bandwidth up to 140 MHz. The effective diameter as derived from directional response measurements is 240 microm at frequencies beyond 15 MHz.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17941384     DOI: 10.1109/tuffc.2007.462

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  11 in total

1.  Broadband optical ultrasound sensor with a unique open-cavity structure.

Authors:  Colin M Chow; Yun Zhou; Yunbo Guo; Theodore B Norris; Xueding Wang; Cheri X Deng; Jing Yong Ye
Journal:  J Biomed Opt       Date:  2011 Jan-Feb       Impact factor: 3.170

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Membrane Hydrophones: Theory Versus Experiment.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-24       Impact factor: 2.725

4.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

5.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part II: Validation for ARFI and Pulsed Doppler Waveforms.

Authors:  Keith A Wear; Anant Shah; Aoife M Ivory; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

6.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part I: Theory and Impact on Diagnostic Safety Indexes.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

7.  Hydrophone Spatial Averaging Artifacts for ARFI Beams from Array Transducers.

Authors:  Keith Wear; Anant Shah; Aoife M Ivory; Christian Baker
Journal:  IEEE Int Ultrason Symp       Date:  2020

8.  Correction for Spatial Averaging Artifacts for Circularly-Symmetric Pressure Beams Measured with Membrane Hydrophones.

Authors:  Keith Wear; Anant Shah; Christian Baker
Journal:  IEEE Int Ultrason Symp       Date:  2020

9.  Directivity and Frequency-Dependent Effective Sensitive Element Size of a Reflectance-Based Fiber-Optic Hydrophone: Predictions From Theoretical Models Compared With Measurements.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

10.  Development of calibration techniques for ultrasonic hydrophone probes in the frequency range from 1 to 100 MHz.

Authors:  S Umchid; R Gopinath; K Srinivasan; P A Lewin; A S Daryoush; L Bansal; M El-Sherif
Journal:  Ultrasonics       Date:  2008-10-21       Impact factor: 2.890

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.