Literature DB >> 17939161

The combined use of thermal desorption and selected ion flow tube mass spectrometry for the quantification of xylene and toluene in air.

Brian M Ross1, Natasha Vermeulen.   

Abstract

Thermal desorption (TD) is commonly employed for volatile chemical analysis, it being the method of choice for occupational health and safety monitoring. TD allows for offline capture of volatiles onto a solid sorbent followed by desorption and analysis at a later time. Although TD is routinely used in conjunction with gas chromatography (TD-GC), the assay throughput is low and requires the use of gas standards for quantification. Another technique increasingly employed for volatile chemical analysis, selected ion flow tube mass spectrometry (SIFT-MS), is capable of real-time absolute (i.e. without calibration standards) quantification of volatile chemicals present at single digit parts per billion or higher concentrations. SIFT-MS is, however, normally used for online direct analysis of gas samples rather than offline collection and analysis. The goal of this study was to determine whether a combination of TD and SIFT-MS could be used to quantify volatile compounds, specifically xylene and toluene, more rapidly than TD-GC and without the need for calibration standards. SIFT-MS was able to quantify xylene and toluene levels within 45 s of desorption. Due to the robustness of the SIFT-MS analysis in the presence of water vapour and other major components of air, the purging of tubes usually required to remove these constituents during the TD cycle was not required, therefore reducing the TD cycle time. Comparing the quantity of xylene and toluene applied to the TD tube with the absolute levels quantified by SIFT-MS subsequent to desorption suggested a recovery of over 95% of the applied compound. We conclude that the combination of TD and SIFT-MS allows more rapid and accurate quantification of xylene and toluene (compared with TD-GC) to be achieved without the need for calibration standards, features which may be advantageous in applications requiring rapid analysis and high throughput. Copyright 2007 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17939161     DOI: 10.1002/rcm.3255

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  2 in total

1.  Cross-platform mass spectrometry annotation in breathomics of oesophageal-gastric cancer.

Authors:  Sung-Tong Chin; Andrea Romano; Sophie L F Doran; George B Hanna
Journal:  Sci Rep       Date:  2018-03-23       Impact factor: 4.379

2.  Sub-parts per billion detection of trace volatile chemicals in human breath using selected ion flow tube mass spectrometry.

Authors:  Brian M Ross
Journal:  BMC Res Notes       Date:  2008-07-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.