EBRA migration patterns of the Plasmacup with ceramic or polyethylene inserts: a randomised study.

U Ochs1, T Ilchmann, B G Ochs, J Marx, K Brunnhuber, M Lüem, K Weise.   

Abstract

AIM: In this prospective randomised study, the influence of different bearing materials on migration and wear was measured and their effect on the function of the artificial joint and the patient outcome was investigated. Mid-term results were recorded so that recommendations can be made on the use of certain bearings, which minimise wear and thus the danger of subsequent aseptic loosening.
METHOD: Sixty-six patients met the inclusion criteria and were willing to take part in the study. These patients were randomised to 2 groups. All of them had total hip arthroplasty with implantation of a cementless Bicontact stem and Plasmacup using a cementless press-fit technique. Thirty-five of these patients were given a ceramic-ceramic bearing and 31 patients a ceramic-polyethylene bearing (gamma sterilised/nitrogen environment). At the most recent follow-up, they underwent detailed clinical and radiological examination and evaluation by means of the Harris Hip Score, Hannover function questionnaire and single-film X-ray analysis (EBRA).
RESULTS: The overall follow-up rate was 65.2 % (43 of 66) and the mean follow-up period was 8.1 (7.1 - 9.2) years. The median Harris Hip Score at the time of follow-up was 90.1 (58.7 - 99.9) points. The average Hannover function score was 87.14 % (63.9 - 100). In 4 of 66 cases (6.1 %) there was a tendency for the Plasmacup to subsidence in the first postoperative months that was slight but detectable by EBRA; however, this stopped subsequently. This primary subsidence was independent of the chosen bearing material. No significant difference in the clinical and radiological parameters was found between the two groups.
CONCLUSION: The very good results with regard to the rate of loosening confirm the press-fit cup fixation concept. The study shows a similar medium-term result for the ceramic-ceramic and ceramic-polyethylene bearing so that use of both bearings can continue to be recommended. Only long-term studies with sufficiently large numbers of patients will be able to show whether significant differences can be detected between the two slide bearings with regard to wear and migration behaviour and so that a recommendation can be given to the surgeon.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17939093     DOI: 10.1055/s-2007-965655

Source DB:  PubMed          Journal:  Z Orthop Unfall        ISSN: 1864-6697            Impact factor:   0.923


  7 in total

1.  Comparative effectiveness of ceramic-on-ceramic implants in stemmed hip replacement: a multinational study of six national and regional registries.

Authors:  Art Sedrakyan; Stephen Graves; Barbara Bordini; Miquel Pons; Leif Havelin; Susan Mehle; Elizabeth Paxton; Thomas Barber; Guy Cafri
Journal:  J Bone Joint Surg Am       Date:  2014-12-17       Impact factor: 5.284

2.  Is there any difference in survivorship of total hip arthroplasty with different bearing surfaces? A systematic review and network meta-analysis.

Authors:  Si Yin; Dangfeng Zhang; Hui Du; Heng Du; Zhanhai Yin; Yusheng Qiu
Journal:  Int J Clin Exp Med       Date:  2015-11-15

3.  A comparative study of "plasmacup" and "porous-coated" acetabular components: survival after 10 to 12 years of follow-up.

Authors:  José Ricardo Negreiros Vicente; Carlos Antonio Soares Ulhoa; Marcio Katz; Renato Dainesi Addeo; Alberto Tesconi Croci
Journal:  Clinics (Sao Paulo)       Date:  2010       Impact factor: 2.365

Review 4.  Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence.

Authors:  Art Sedrakyan; Sharon-Lise T Normand; Stefan Dabic; Samantha Jacobs; Stephen Graves; Danica Marinac-Dabic
Journal:  BMJ       Date:  2011-11-29

5.  Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty.

Authors:  C Zilkens; S Djalali; B Bittersohl; T Kälicke; C N Kraft; R Krauspe; Marcus Jäger
Journal:  Eur J Med Res       Date:  2011-03-28       Impact factor: 2.175

6.  Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro.

Authors:  Ana Laura Puente Reyna; Marcus Jäger; Thilo Floerkemeier; Sven Frecher; Karl-Stefan Delank; Christoph Schilling; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2016-09-19       Impact factor: 3.411

7.  The Influence of Tribological Pairings and Other Factors on Migration Patterns of Short Stems in Total Hip Arthroplasty.

Authors:  Thilo Floerkemeier; Michael Schwarze; Christof Hurschler; Jens Gronewold; Henning Windhagen; Gabriela von Lewinski; Stefan Budde
Journal:  Biomed Res Int       Date:  2017-04-13       Impact factor: 3.411