Literature DB >> 17939035

Does computer-aided detection (CAD) contribute to the performance of digital mammography in a self-referred population?

Beniamino Brancato1, Nehmat Houssami, Damiana Francesca, Simonetta Bianchi, Gabriella Risso, Sandra Catarzi, Renzo Taschini, Marco Rosselli Del Turco, Stefano Ciatto.   

Abstract

BACKGROUND: Recent evidence suggests that computer-aided detection (CAD) may have a negative impact on the interpretation of mammography-this necessitates timely evaluation of CAD in practice. We report a retrospective study of the incremental effect of CAD on the accuracy of full-field digital mammography (DM) as applied prospectively in breast assessment.
METHODS: Subjects were all consecutive women attending a self-referral breast centre in Florence between September 2005 and January 2007 (N = 3,425). DM was reported without, then with, CAD according to a standard protocol; all mammograms recalled on the basis of either the radiologist's reading alone, or the radiologist's reading after viewing CAD, were recalled to assessment.
RESULTS: Overall recall rate (RR) was 13.1% and 107 cancers were diagnosed (90 invasive cancers, 8 DCIS, 9 malignant on cytology). The use of CAD allowed the additional detection of 5 cancers (three invasive cancers, one DCIS, one malignant on cytology) and caused one additional benign surgical biopsy, with a relative RR of 4.9%, and an incremental RR of 1.17%. The cancer detection rate (CDR) of DM interpreted with the use of CAD was 3.12% and did not significantly differ from the CDR of 2.9% based on DM without CAD (chi(2) = 3.2, P = 0.07).
CONCLUSION: While the increase in CDR with the use of CAD only approached statistical significance, representing modest gains in absolute terms, the incremental number of cancers detected justifies the incremental recall and benign surgical biopsy attributable to CAD use. In our clinical setting, these data suggest more benefit than harm in using CAD with DM, and we will continue the use of CAD with ongoing monitoring of patient outcomes.

Entities:  

Mesh:

Year:  2007        PMID: 17939035     DOI: 10.1007/s10549-007-9786-2

Source DB:  PubMed          Journal:  Breast Cancer Res Treat        ISSN: 0167-6806            Impact factor:   4.872


  7 in total

1.  Computer-aided detection of clustered microcalcifications in digital breast tomosynthesis: a 3D approach.

Authors:  Berkman Sahiner; Heang-Ping Chan; Lubomir M Hadjiiski; Mark A Helvie; Jun Wei; Chuan Zhou; Yao Lu
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  False positive marks on unsuspicious screening mammography with computer-aided detection.

Authors:  Mary C Mahoney; Karthikeyan Meganathan
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

3.  Effectiveness of computer-aided detection in community mammography practice.

Authors:  Joshua J Fenton; Linn Abraham; Stephen H Taplin; Berta M Geller; Patricia A Carney; Carl D'Orsi; Joann G Elmore; William E Barlow
Journal:  J Natl Cancer Inst       Date:  2011-07-27       Impact factor: 13.506

4.  Short-term outcomes of screening mammography using computer-aided detection: a population-based study of medicare enrollees.

Authors:  Joshua J Fenton; Guibo Xing; Joann G Elmore; Heejung Bang; Steven L Chen; Karen K Lindfors; Laura-Mae Baldwin
Journal:  Ann Intern Med       Date:  2013-04-16       Impact factor: 25.391

5.  Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

Authors:  Ryusuke Murakami; Shinichiro Kumita; Hitomi Tani; Tamiko Yoshida; Kenichi Sugizaki; Tomoyuki Kuwako; Tomonari Kiriyama; Kenta Hakozaki; Emi Okazaki; Keiko Yanagihara; Shinya Iida; Shunsuke Haga; Shinichi Tsuchiya
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

Review 6.  Is single reading with computer-aided detection (CAD) as good as double reading in mammography screening? A systematic review.

Authors:  Edward Azavedo; Sophia Zackrisson; Ingegerd Mejàre; Marianne Heibert Arnlind
Journal:  BMC Med Imaging       Date:  2012-07-24       Impact factor: 1.930

7.  Three-Dimensional Computer-Aided Detection of Microcalcification Clusters in Digital Breast Tomosynthesis.

Authors:  Ji-Wook Jeong; Seung-Hoon Chae; Eun Young Chae; Hak Hee Kim; Young-Wook Choi; Sooyeul Lee
Journal:  Biomed Res Int       Date:  2016-05-04       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.