Literature DB >> 17938492

Clinical assessment of primary stability of endosseous implants placed in the incisor region, using resonance frequency analysis methodology: an in vivo study.

R Ramakrishna1, Sanjna Nayar.   

Abstract

AIM: To evaluate the effect of immediate loading on the primary stability of endosseous implants placed in the anterior incisor region by mapping the stability, using resonance frequency analysis, over a period of time.
MATERIALS AND METHODS: A total of eight implants (Zimmer Screw-Vent) were placed in four patients. The Osstell resonance frequency analyzer was used to determine the primary stability at baseline (day 1), 15 th day, 30 th day, 60 th day, and 90 th day for each of the eight implants. Analysis of data was done using SPSS (Statistical Package for Social Science; version 4.0.1).
RESULTS: All implants showed adequate initial stability at baseline with an ISQ > 50. Implant nos. 1, 3, 4, 7, and 8 showed a high initial stability at baseline (ISQ > 65), following which a decrease in the stability was recorded during the 15 th day, 30 th day, and 60 th day. By the 90 th day, the stability values were nearly equivalent to those obtained at baseline. The highest mean stability value was recorded on the day of implant placement. The lowest mean stability recording was obtained on the 30 th day after implant osteotomy. By the 90 th day, the mean stability value was nearly equivalent to that obtained at baseline.
CONCLUSIONS: Within the limitations of this study, it can be concluded that immediate loading of implants placed in the maxillary and mandibular incisor region does not seem to have an adverse effect on the osseointegration of implants, which achieved a high primary stability. The use of the resonance frequency analyzer as a tool to monitor the variation in the stability of the implants over a period of time has been validated.

Entities:  

Mesh:

Year:  2007        PMID: 17938492     DOI: 10.4103/0970-9290.35826

Source DB:  PubMed          Journal:  Indian J Dent Res        ISSN: 0970-9290


  5 in total

Review 1.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

2.  Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study.

Authors:  Frederico Santos Lages; Dhelfeson Willya Douglas-de-Oliveira; Guilherme Siqueira Ibelli; Fatimah Assaf; Thallita Pereira Queiroz; Fernando Oliveira Costa
Journal:  PLoS One       Date:  2017-07-24       Impact factor: 3.240

3.  Assessment of implant stability during various stages of healing placed immediately following extraction in an overdenture situation.

Authors:  Ashwin Thomas Koshy; T Aby Mathew; Nicholas Mathew; Angel Mary Joseph
Journal:  J Indian Prosthodont Soc       Date:  2017 Jan-Mar

Review 4.  Immediate loading implants: review of the critical aspects.

Authors:  L Tettamanti; C Andrisani; M Andreasi Bassi; R Vinci; J Silvestre-Rangil; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-09-27

5.  A comparative study on the stress distribution around dental implants in three arch form models for replacing six implants using finite element analysis.

Authors:  Maryam Zarei; Mahmoud Jahangirnezhad; Hojatollah Yousefimanesh; Maryam Robati; Hossein Robati
Journal:  J Indian Soc Periodontol       Date:  2018 Mar-Apr
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.