Literature DB >> 17937201

Lubrication regimes in lumbar total disc arthroplasty.

A Shaheen1, D E T Shepherd.   

Abstract

A number of total disc arthroplasty devices have been developed. Some concern has been expressed that wear may be a potential failure mode for these devices, as has been seen with hip arthroplasty. The aim of this paper was to investigate the lubrication regimes that occur in lumbar total disc arthroplasty devices. The disc arthroplasty was modelled as a ball-and-socket joint. Elastohydrodynamic lubrication theory was used to calculate the minimum film thickness of the fluid between the bearing surfaces. The lubrication regime was then determined for different material combinations, size of implant, and trunk velocity. Disc arthroplasties with a metal-polymer or metal-metal material combination operate with a boundary lubrication regime. A ceramic-ceramic material combination has the potential to operate with fluid-film lubrication. Disc arthroplasties with a metal-polymer or metal-metal material combination are likely to generate wear debris. In future, it is worth considering a ceramic-ceramic material combination as this is likely to reduce wear.

Entities:  

Mesh:

Year:  2007        PMID: 17937201     DOI: 10.1243/09544119JEIM204

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  6 in total

Review 1.  Design concepts in lumbar total disc arthroplasty.

Authors:  Fabio Galbusera; Chiara M Bellini; Thomas Zweig; Stephen Ferguson; Manuela T Raimondi; Claudio Lamartina; Marco Brayda-Bruno; Maurizio Fornari
Journal:  Eur Spine J       Date:  2008-10-23       Impact factor: 3.134

2.  The effect of anterior-posterior shear load on the wear of ProDisc-L TDR.

Authors:  R Vicars; P J Hyde; T D Brown; J L Tipper; E Ingham; J Fisher; R M Hall
Journal:  Eur Spine J       Date:  2010-04-18       Impact factor: 3.134

3.  We Need to Talk about Lumbar Total Disc Replacement.

Authors:  Stephen Beatty
Journal:  Int J Spine Surg       Date:  2018-08-03

4.  PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis.

Authors:  H Xin; Det Shepherd; Kd Dearn
Journal:  Open Biomed Eng J       Date:  2012-05-09

5.  ISASS Policy Statement - Lumbar Artificial Disc.

Authors:  Jack Zigler; Rolando Garcia
Journal:  Int J Spine Surg       Date:  2015-03-12

6.  The fundamentals of biotribology and its application to spine arthroplasty.

Authors:  Megan L Harper; Andrew Dooris; Philippe E Paré
Journal:  SAS J       Date:  2009-12-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.