Literature DB >> 17936114

A novel potentiometric biosensor for selective L-cysteine determination using L-cysteine-desulfhydrase producing Trichosporon jirovecii yeast cells coupled with sulfide electrode.

Saad S M Hassan1, Ashraf F el-Baz, Hisham S M Abd-Rabboh.   

Abstract

Trichosporon jirovecii yeast cells are used for the first time as a source of L-cysteine desulfhydrase enzyme (EC 4.4.1.1) and incorporated in a biosensor for determining L-cysteine. The cells are grown under cadmium stress conditions to increase the expression level of the enzyme. The intact cells are immobilized on the membrane of a solid-state Ag2S electrode to provide a simple L-cysteine responsive biosensor. Upon immersion of the sensor in L-cysteine containing solutions, L-cysteine undergoes enzymatic hydrolysis into pyruvate, ammonia and sulfide ion. The rate of sulfide ion formation is potentiometrically measured as a function of L-cysteine concentration. Under optimized conditions (phosphate buffer pH 7, temperature 37+/-1 degrees C and actual weight of immobilized yeast cells 100 mg), a linear relationship between L-cysteine concentration and the initial rate of sulfide liberation (dE/dt) is obtained. The sensor response covers the concentration range of 0.2-150 mg L(-1) (1.7-1250 micromol L(-1)) L-cysteine. Validation of the assay method according to the quality control/quality assurance standards (precision, accuracy, between-day variability, within-day reproducibility, range of measurements and lower limit of detection) reveals remarkable performance characteristics of the proposed biosensor. The sensor is satisfactorily utilized for determination of L-cysteine in some pharmaceutical formulations. The lower limit of detection is approximately 1 micromol L(-1) and the accuracy and precision of the method are 97.5% and +/-1.1%, respectively. Structurally similar sulfur containing compounds such as glutathione, cystine, methionine, and D-cysteine do no interfere.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17936114     DOI: 10.1016/j.aca.2007.09.007

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  1 in total

1.  Electrochemical oxidation of cysteine at a film gold modified carbon fiber microelectrode its application in a flow-through voltammetric sensor.

Authors:  Lai-Hao Wang; Wen-Shiuan Huang
Journal:  Sensors (Basel)       Date:  2012-03-14       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.