In vitro rapid intraoral adjustment of porcelain prostheses using a high-speed dental handpiece.

Xiao-Fei Song1, Ling Yin, Yi-Gang Han, Hui Wang.   

Abstract

In vitro rapid intraoral adjustment of porcelain prostheses was conducted using a high-speed dental handpiece and diamond bur. The adjustment process was characterized by measurement of removal forces and energy, with scanning electron microscopic (SEM) observation of porcelain debris, surfaces and subsurface damage produced as a function of operational feed rate. Finite element analysis (FEA) was applied to evaluate subsurface stress distributions and degrees of subsurface damage. The results show that an increase in feed rate resulted in increases in both tangential and normal forces (analysis of variance (ANOVA), P<0.01). When the feed rate approached the highest rate of 60mm min(-1) at a fixed depth of cut of 100microm, the tangential force was nearly seven times that at the lowest feed rate of 15mm min(-1). Consequently, the specific removal energy increased significantly (ANOVA, P<0.01), and the maximum depth of subsurface damage obtained was approximately 110 and 120microm at the highest feed rate of 60mm min(-1) using SEM and FEA, respectively. The topographies of both the adjusted porcelain surfaces and the debris demonstrate microscopically that porcelain was removed via brittle fracture and plastic deformation. Clinicians must be cautious when pursuing rapid dental adjustments, because high operational energy, larger forces and severe surface and subsurface damage can be induced.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17931987     DOI: 10.1016/j.actbio.2007.08.006

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  3 in total

Review 1.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

2.  Rhombohedral Phase Formation in Yttria-Stabilized Zirconia Induced by Dental Technical Tools and Its Impact on Dental Applications.

Authors:  Markus Wertz; Michael Benno Schmidt; Hieronymus Hoelzig; Maximilian Wagner; Bernd Abel; Gert Kloess; Sebastian Hahnel; Andreas Koenig
Journal:  Materials (Basel)       Date:  2022-06-24       Impact factor: 3.748

3.  Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses.

Authors:  Halil İbrahim Kılınç; Bülent Kesim; Hasan Önder Gümüş; Mehmet Dinçel; Selçuk Erkaya
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.