Isolation of Legionella species/serogroups from water cooling systems compared with potable water systems in Spanish healthcare facilities.

J-M Rivera1, L Aguilar, J J Granizo, A Vos-Arenilla, M-J Giménez, J-M Aguiar, J Prieto.   

Abstract

Surveillance of Legionella spp. in hospital water systems was performed in forty-four inpatient healthcare facilities in Spain during 2005-2006. A total of 2,341 samples were collected: 470 from cooling systems (cooling towers) and 1,871 from potable water systems. The latter included 211 from cold-water tanks and 260 from hot-water tanks, totalling 471 from central water reservoirs 136 from showers, 1,172 from unfiltered taps and 92 from filtered taps, totalling 1,400 from peripheral points. Temperature, chlorine levels and the presence of Legionella spp. were determined. In all, 373 (15.9%) samples yielded Legionella spp. Significantly higher isolation rates were obtained from cooling towers (23.8%) versus cold- and hot-water tanks (approximately 4.7%), due to the significantly higher number of samples positive for serogroup 1 (19.4 vs 0.9-3.5%). In potable water systems, no differences were found between central water tanks and showers, but significant differences in isolation rates between central water tanks and unfiltered taps were observed (4.7 vs 19.6%) due to differences in non-serogroup 1 L. pneumophila. Filters significantly decreased isolation rates of these serotypes (11 vs 0%). Some seasonal differences were noted, with higher isolation rates in summer for legionella serogroup 1 in cooling systems and for L. pneumophila serogroups 2-14 in potable water systems. In regression models, higher temperatures were associated with colonisation in cooling systems, while lower chlorine levels were associated with colonisation in potable water systems.

Entities:  

Mesh:

Year:  2007        PMID: 17931746     DOI: 10.1016/j.jhin.2007.07.022

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  7 in total

1.  A Supervised Statistical Learning Approach for Accurate Legionella pneumophila Source Attribution during Outbreaks.

Authors:  Andrew H Buultjens; Kyra Y L Chua; Sarah L Baines; Jason Kwong; Wei Gao; Zoe Cutcher; Stuart Adcock; Susan Ballard; Mark B Schultz; Takehiro Tomita; Nela Subasinghe; Glen P Carter; Sacha J Pidot; Lucinda Franklin; Torsten Seemann; Anders Gonçalves Da Silva; Benjamin P Howden; Timothy P Stinear
Journal:  Appl Environ Microbiol       Date:  2017-10-17       Impact factor: 4.792

2.  Legionella detection and subgrouping in water air-conditioning cooling tower systems in Kuwait.

Authors:  Qadreyah Al-Matawah; Sameer Al-Zenki; Ahmad Al-Azmi; Tahani Al-Waalan; Fadila Al-Salameen; Ahmad Ben Hejji
Journal:  Environ Sci Pollut Res Int       Date:  2015-02-21       Impact factor: 4.223

3.  Distribution of Legionella species from environmental water sources of public facilities and genetic diversity of L. pneumophila serogroup 1 in South Korea.

Authors:  Hae Kyung Lee; Jung Im Shim; Hye Eun Kim; Jae Yon Yu; Yeon Ho Kang
Journal:  Appl Environ Microbiol       Date:  2010-08-06       Impact factor: 4.792

4.  Is a Proactive Approach to Controlling Legionella in the Environment Justified?

Authors:  Daniela Glažar Ivče; Dobrica Rončević; Marina Šantić; Arijana Cenov; Dijana Tomić Linšak; Vladimir Mićović; Dražen Lušić; Marin Glad; Davor Ljubas; Darija Vukić Lušić
Journal:  Food Technol Biotechnol       Date:  2021-09       Impact factor: 3.918

5.  High prevalence, genetic diversity and intracellular growth ability of Legionella in hot spring environments.

Authors:  Tian Qin; Gebin Yan; Hongyu Ren; Haijian Zhou; Huanxin Wang; Ying Xu; Mingqiang Zhao; Hong Guan; Machao Li; Zhujun Shao
Journal:  PLoS One       Date:  2013-03-18       Impact factor: 3.240

6.  Applicability assessment of ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ to the eradication of Legionella in rainwater storage tanks for household use.

Authors:  Kozue Oana; Michiko Kobayashi; Dai Yamaki; Tsukasa Sakurada; Noriyuki Nagano; Yoshiyuki Kawakami
Journal:  Int J Nanomedicine       Date:  2015-08-04

7.  First Case of Legionnaire's Disease Caused by Legionella anisa in Spain and the Limitations on the Diagnosis of Legionella non-pneumophila Infections.

Authors:  Lucianna Vaccaro; Fernando Izquierdo; Angela Magnet; Carolina Hurtado; Mireya B Salinas; Thiago Santos Gomes; Santiago Angulo; Santiago Salso; Jesús Pelaez; Maria Isabel Tejeda; Almudena Alhambra; Carmen Gómez; Ana Enríquez; Eva Estirado; Soledad Fenoy; Carmen Del Aguila
Journal:  PLoS One       Date:  2016-07-21       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.