Literature DB >> 17931636

Is hydrophilic interaction chromatography with silica columns a viable alternative to reversed-phase liquid chromatography for the analysis of ionisable compounds?

David V McCalley1.   

Abstract

The separation of acidic, neutral and particularly basic solutes was investigated using a bare silica column, mostly under hydrophilic interaction chromatography (HILIC) conditions with water concentrations >2.5% and with >70% acetonitrile (ACN). Profound changes in selectivity could be obtained by judicious selection of the buffer and its pH. Acidic solutes had low retention or showed exclusion in ammonium formate buffers, but were strongly retained when using trifluoroacetic acid (TFA) buffers, possibly due to suppression of repulsion of the solute anions from ionised silanol groups at the low (s)(s)pH of TFA solutions of aqueous ACN. At high buffer pH, the ionisation of weak bases was suppressed, reducing ionic (and possibly hydrophilic retention) leading to further opportunities for manipulation of selectivity. Peak shapes of basic solutes were excellent in ammonium formate buffers, and overloading effects, which are a major problem for charged bases in RPLC, were relatively insignificant in analytical separations using this buffer. HILIC separations were ideal for fast analysis of ionised bases, due to the low viscosity of mobile phases with high ACN content, and the favourable Van Deemter curves which resulted from higher solute diffusivities.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17931636     DOI: 10.1016/j.chroma.2007.09.047

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

Review 1.  Hydrophilic interaction liquid chromatography (HILIC)--a powerful separation technique.

Authors:  Bogusław Buszewski; Sylwia Noga
Journal:  Anal Bioanal Chem       Date:  2011-08-31       Impact factor: 4.142

2.  Application of Hydrophilic Interaction Liquid Chromatography for the Quantification of Flavonoids in Genista tinctoria Extract.

Authors:  Aleksandra Sentkowska; Magdalena Biesaga; Krystyna Pyrzynska
Journal:  J Anal Methods Chem       Date:  2016-06-28       Impact factor: 2.193

3.  Implementation of HILIC-UV technique for the determination of moxifloxacin and fluconazole in raw materials and pharmaceutical eye gel.

Authors:  Eman Yosrey; Heba Elmansi; Zeinab A Sheribah; Mohammed El-Sayed Metwally
Journal:  Sci Rep       Date:  2022-08-04       Impact factor: 4.996

4.  Hydrophilic Interaction Liquid Chromatography Coupled to Mass Spectrometry and Multivariate Analysis of the De Novo Pyrimidine Pathway Metabolites.

Authors:  Paula Galeano Garcia; Barbara H Zimmermann; Chiara Carazzone
Journal:  Biomolecules       Date:  2019-07-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.