Literature DB >> 17931048

Continuous glucose monitors: the long-awaited watch dogs?

I M E Wentholt1, J B L Hoekstra, J H Devries.   

Abstract

To date, several continuous glucose sensors have been developed and launched in the U.S. and European markets, though large-scale application in standard diabetes care still awaits its breakthrough. This report offers an overview of the current applications and clinically relevant aspects of continuous glucose monitors (CGMs), e.g., the calibration procedure, interpretation of continuous glucose data, and some important limitations. It is still difficult to state with certainty that CGMs allow effective improvement in glycemic control for the majority of patients with type 1 diabetes, in view of the paucity of controlled studies showing an impact on hemoglobin A1c or frequency of hypoglycemia, even if such a tendency seems to emerge from most non-controlled intervention trials. Future controlled trials should also take into account patient-related outcomes, to evaluate the effect of CGMs on health status, treatment satisfaction, and fear of hypoglycemia. Increased accuracy and reimbursement are key to further implementation of CGMs.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17931048     DOI: 10.1089/dia.2007.0215

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  12 in total

1.  Evaluation of implementation of a fully automated algorithm (enhanced model predictive control) in an interacting infusion pump system for establishment of tight glycemic control in medical intensive care unit patients.

Authors:  Roman Kulnik; Johannes Plank; Christoph Pachler; Malgorzata E Wilinska; Andrea Groselj-Strele; Doris Röthlein; Matthias Wufka; Norman Kachel; Karl Heinz Smolle; Sabine Perl; Thomas Rudolf Pieber; Roman Hovorka; Martin Ellmerer
Journal:  J Diabetes Sci Technol       Date:  2008-11

2.  Tight glycemic control in the hospital.

Authors:  Martin Ellmerer; Christoph Pachler; Johannes Plank
Journal:  J Diabetes Sci Technol       Date:  2008-07

3.  Continuous glucose monitoring accuracy results vary between assessment at home and assessment at the clinical research center.

Authors:  Yoeri M Luijf; Angelo Avogaro; Carsten Benesch; Daniela Bruttomesso; Claudio Cobelli; Martin Ellmerer; Lutz Heinemann; Julia K Mader; J Hans DeVries
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

4.  Sense and nonsense in sensors.

Authors:  J Hermanides; J H DeVries
Journal:  Diabetologia       Date:  2010-01-10       Impact factor: 10.122

5.  Premeal injection of rapid-acting insulin reduces postprandial glycemic excursions in type 1 diabetes.

Authors:  Yoeri M Luijf; Arianne C van Bon; Joost B Hoekstra; J Hans Devries
Journal:  Diabetes Care       Date:  2010-08-06       Impact factor: 19.112

6.  Evaluation of the performance of a novel system for continuous glucose monitoring.

Authors:  Eva Zschornack; Christina Schmid; Stefan Pleus; Manuela Link; Hans-Martin Klötzer; Karin Obermaier; Michael Schoemaker; Monika Strasser; Gerhard Frisch; Günther Schmelzeisen-Redeker; Cornelia Haug; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2013-07-01

Review 7.  Continuous Glucose Monitoring: Impact on Hypoglycemia.

Authors:  Cornelis A J van Beers; J Hans DeVries
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

Review 8.  Progress toward an in vivo surface-enhanced Raman spectroscopy glucose sensor.

Authors:  Olga Lyandres; Jonathan M Yuen; Nilam C Shah; Richard P VanDuyne; Joseph T Walsh; Matthew R Glucksberg
Journal:  Diabetes Technol Ther       Date:  2008-08       Impact factor: 6.118

Review 9.  Continuous glucose monitoring systems for type 1 diabetes mellitus.

Authors:  Miranda Langendam; Yoeri M Luijf; Lotty Hooft; J Hans Devries; Aart H Mudde; Rob J P M Scholten
Journal:  Cochrane Database Syst Rev       Date:  2012-01-18

10.  Current application of continuous glucose monitoring in the treatment of diabetes: pros and cons.

Authors:  Jeroen Hermanides; Moshe Phillip; J Hans DeVries
Journal:  Diabetes Care       Date:  2011-05       Impact factor: 19.112

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.