Sensitivity for detection of patent foramen ovale increased with increasing number of contrast injections: a descriptive study with contrast transesophageal echocardiography.

Magnus C Johansson1, Hrodmar Helgason, Mikael Dellborg, Peter Eriksson.   

Abstract

OBJECTIVE: We sought to study the diagnostic yield of increasing numbers of contrast injections for detection of patent foramen ovale (PFO) during transesophageal echocardiography.
METHODS: Contrast was injected twice during each of 10 provocations to 30 patients screened for PFO. Injections were given during quiet respiration, early Valsalva (starting 3-5 seconds before injection), late Valsalva (starting 3-5 seconds after injection), Mueller maneuver, coughing, bed tilt during early Valsalva, after nitroglycerin spray during both quiet respiration, and early Valsalva.
RESULTS: The number of detected PFOs increased as the number of injections increased (r = 0.79, P < .01). Five injections per patient detected all 11 large PFOs. To eventually detect all 14 PFOs among the 30 study patients required a total of 11 injections per patient.
CONCLUSION: The sensitivity for PFO detection increased when additional contrast injections were given. At least 5 injections are required to safely detect or rule out the presence of a PFO.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17928199     DOI: 10.1016/j.echo.2007.08.030

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  7 in total

1.  Prevalence of intracardiac shunting in children with sickle cell disease and stroke.

Authors:  Michael M Dowling; Nancy Lee; Charles T Quinn; Zora R Rogers; Deborah Boger; Naveed Ahmad; Claudio Ramaciotti; George R Buchanan
Journal:  J Pediatr       Date:  2009-12-21       Impact factor: 4.406

Review 2.  Intracardiac shunting and stroke in children: a systematic review.

Authors:  Michael M Dowling; Catherine M Ikemba
Journal:  J Child Neurol       Date:  2011-01       Impact factor: 1.987

Review 3.  Modern management of a patent foramen ovale.

Authors:  G S Kanaganayagam; I S Malik
Journal:  JRSM Cardiovasc Dis       Date:  2012-10-31

4.  Reproducibility of right-to-left shunt quantification using transthoracic contrast echocardiography in hereditary haemorrhagic telangiectasia.

Authors:  V M M Vorselaars; S Velthuis; M P Huitema; A E Hosman; C J J Westermann; R J Snijder; J J Mager; M C Post
Journal:  Neth Heart J       Date:  2018-04       Impact factor: 2.380

5.  Seven-year follow-up of percutaneous closure of patent foramen ovale.

Authors:  Naqibullah Mirzada; Per Ladenvall; Per-Olof Hansson; Magnus Carl Johansson; Eva Furenäs; Peter Eriksson; Mikael Dellborg
Journal:  Int J Cardiol Heart Vessel       Date:  2013-11-14

6.  Absence of significant aortic regurgitation seven years after closure of patent foramen ovale.

Authors:  Naqibullah Mirzada; Per Ladenvall; Magnus C Johansson
Journal:  Int J Cardiol Heart Vessel       Date:  2014-07-27

7.  Diagnosis of Patent Foramen Ovale: The Combination of Contrast Transcranial Doppler, Contrast Transthoracic Echocardiography, and Contrast Transesophageal Echocardiography.

Authors:  Xiaoxue Yang; Hua Wang; Yajuan Wei; Nina Zhai; Baomin Liu; Xiaopeng Li
Journal:  Biomed Res Int       Date:  2020-02-23       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.