Literature DB >> 17926960

Microdosimetric study for secondary neutrons in phantom produced by a 290 MeV/nucleon carbon beam.

Satoru Endo1, Kenichi Tanaka, Masashi Takada, Yoshihiko Onizuka, Nobuyuki Miyahara, Tatsuhiko Sato, Masayori Ishikawa, Naoko Maeda, Naofumi Hayabuchi, Kiyoshi Shizuma, Masaharu Hoshi.   

Abstract

Absorbed doses from main charged-particle beams and charged-particle fragments have been measured with high accuracy for particle therapy, but there are few reports for doses from neutron components produced as fragments. This study describes the measurements on neutron doses produced by carbon beams; microdosimetric distributions of secondary neutrons produced by 290 MeV/nucleon carbon beams have been measured by using a tissue equivalent proportional counter at the Heavy Ion Medical Accelerator in Chiba, Japan at the National Institute of Radiological Sciences. The microdosimetric distributions of the secondary neutron were measured on the distal and lateral faces of a body-simulated acrylic phantom (300 mm height x 300 mm width x 253 mm thickness). To confirm the dose measurements, the neutron energy spectra produced by incident carbon beams in the acrylic phantom were simulated by the particle and heavy ion transport code system. The absorbed doses obtained by multiplying the simulated neutron energy spectra with the kerma factor calculated by MCNPX agree with the corresponding experimental data fairly well. Downstream of the Bragg peak, the ratio of the neutron dose to the carbon dose at the Bragg peak was found to be a maximum of 1.4 x 10(-4) and the ratio of neutron dose was a maximum of 3.0 x 10(-7) at a lateral face of the acrylic phantom. The ratios of neutrons to charged particle fragments were 11% to 89% in the absorbed doses at the lateral and the distal faces of the acrylic phantom. We can conclude that the treatment dose will not induce serious secondary neutron effects at distances greater than 90 mm from the Bragg peak in carbon particle therapy.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17926960     DOI: 10.1118/1.2767933

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Measurement of microdosimetric spectra produced from a 290 MeV/n Spread Out Bragg Peak carbon beam.

Authors:  Satoru Endo; Masashi Takada; Hiroki Tanaka; Yoshihiko Onizuka; Kenichi Tanaka; Nobuyuki Miyahara; Hiromi Baba; Ayumu Oishi; Masayori Ishikawa; Masaharu Hoshi; Shinzo Kimura; Masakazu Minematsu; Yuki Morimune; Yasuaki Kojima; Kiyoshi Shizuma
Journal:  Radiat Environ Biophys       Date:  2010-04-18       Impact factor: 1.925

2.  Microdosimetric measurements in the secondary radiation field produced in (12)C-therapy irradiations.

Authors:  F Wissmann; U Giesen; T Klages; D Schardt; G Martino; C Sunil
Journal:  Radiat Environ Biophys       Date:  2010-03-26       Impact factor: 1.925

  2 in total