Improved dose homogeneity in the breast using tissue compensators.

W P Mayles1, J R Yarnold, S Webb.   

Abstract

The improvements achievable by introducing individual tissue compensators in photon therapy of the breast were assessed. In 37 patients the dose ranged from +15% to -10% of the mid target dose using combinations of wedge filters and beam weights alone. With a tissue compensator the dose ranged from +4% to -11% provided that allowance was made for lung attenuation. A megavoltage imaging system is a potential source of the X-ray transmission data which can provide a basis for the calculation of thickness of the compensator.

Entities:  

Mesh:

Year:  1991        PMID: 1792316     DOI: 10.1016/0167-8140(91)90158-d

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  2 in total

1.  Dosimetric evaluation of whole breast radiotherapy using field-in-field technique in early-stage breast cancer.

Authors:  Masahiro Sasaoka; Tomoyuki Futami
Journal:  Int J Clin Oncol       Date:  2011-01-14       Impact factor: 3.402

2.  Anthropomorphic breast phantoms for quality assurance and dose verification.

Authors:  José A Bencomo; Connel Chu; Victor M Tello; Sang Hyun Cho; Geoffrey S Ibbott
Journal:  J Appl Clin Med Phys       Date:  2004-01-01       Impact factor: 2.102