Literature DB >> 17916401

First trimester uterine Doppler and three-dimensional ultrasound placental volume calculation in predicting pre-eclampsia.

Giuseppe Rizzo1, Alessandra Capponi, Ottavia Cavicchioni, Marianne Vendola, Domenico Arduini.   

Abstract

OBJECTIVE: To compare the efficacy of uterine artery Doppler velocimetry and three-dimensional ultrasound placental volume calculation alone or in combination in predicting at 11-14 weeks of gestation those pregnancies who will develop pre-eclampsia. STUDY
DESIGN: This was a prospective study of 348 nulliparous women scheduled for a routine prenatal ultrasound examination at 11-14 weeks. Color and pulsed wave Doppler was used to obtain uterine artery flow velocity waveforms transabdominally and the mean pulsatility index (PI) of the uterine arteries was calculated. The placental volume was measured by three-dimensional ultrasound using the virtual organ computer-aided analysis. Outcome variables considered were pre-eclampsia and pre-eclampsia requiring delivery <32 weeks.
RESULTS: Pre-eclampsia developed in 4.1% of the patients studied and in 1.7% a delivery before 32 weeks was required. Placental volume resulted significantly lower in pregnancies who will develop pre-eclampsia (t=4.636, p<0.003) and this was particularly evident in those pregnancies delivering <32 weeks (t=9.704, p<0.0002). No relationship was found between placental volume and mean uterine artery PI (r=-0.08, p=0.327). Uterine artery PI and placental volume showed similar sensitivities in predicting pre-eclampsia (50% vs. 56%) and pre-eclampsia with delivery <32 weeks (66.7% vs. 66.7%). The combination of uterine artery PI and placental volume gave better results when compared to the single use of one of these parameters (pre-eclampsia sensitivity 68.7%, pre-eclampsia requiring delivery <32 weeks 83.3%).
CONCLUSIONS: The combination of abnormal uterine artery Doppler and low placental volume at 11-14 weeks achieves better results than does either test alone in the prediction of pre-eclampsia.

Entities:  

Mesh:

Year:  2007        PMID: 17916401     DOI: 10.1016/j.ejogrb.2007.08.015

Source DB:  PubMed          Journal:  Eur J Obstet Gynecol Reprod Biol        ISSN: 0301-2115            Impact factor:   2.435


  9 in total

1.  A clinical system for three-dimensional extended-field-of-view ultrasound.

Authors:  E Dyer; U Zeeshan Ijaz; R Housden; R Prager; A Gee; G Treece
Journal:  Br J Radiol       Date:  2012-10       Impact factor: 3.039

2.  First-trimester placental ultrasound and maternal serum markers as predictors of small-for-gestational-age infants.

Authors:  Nadav Schwartz; Mary D Sammel; Rita Leite; Samuel Parry
Journal:  Am J Obstet Gynecol       Date:  2014-03-05       Impact factor: 8.661

3.  Prediction and prevention of hypertensive disorders of pregnancy.

Authors:  Akihide Ohkuchi; Chikako Hirashima; Kayo Takahashi; Hirotada Suzuki; Shigeki Matsubara
Journal:  Hypertens Res       Date:  2016-08-18       Impact factor: 3.872

Review 4.  Pre-eclampsia: pathophysiology, diagnosis, and management.

Authors:  Jennifer Uzan; Marie Carbonnel; Olivier Piconne; Roland Asmar; Jean-Marc Ayoubi
Journal:  Vasc Health Risk Manag       Date:  2011-07-19

5.  Reproducibility of 3-Dimensional Ultrasound Measurements of Placental Volume at Gestational Ages 11 - 14 Weeks.

Authors:  M L Larsen; K V Naver; M M Kjaer; F S Jorgensen; L Nilas
Journal:  Facts Views Vis Obgyn       Date:  2015-12-28

6.  Larger First-Trimester Placental Volumetric Parameters Are Associated With Lower Pressure and More Flow-Mediated Vasodilation of the Fetoplacental Vasculature After Delivery.

Authors:  Emilie Hitzerd; Igna F Reijnders; Annemarie G M G J Mulders; Anton H J Koning; Irwin K M Reiss; A H Jan Danser; Régine P M Steegers-Theunissen; Sinno H P Simons; Maria P H Koster
Journal:  Front Physiol       Date:  2020-01-24       Impact factor: 4.566

Review 7.  Placental Volume and Uterine Artery Doppler in Pregnancy Following In Vitro Fertilization: A Comprehensive Literature Review.

Authors:  Serena Resta; Gaia Scandella; Ilenia Mappa; Maria Elena Pietrolucci; Pavjola Maqina; Giuseppe Rizzo
Journal:  J Clin Med       Date:  2022-09-29       Impact factor: 4.964

8.  Relationship between Plasma D-Dimer Concentration and Three-Dimensional Ultrasound Placental Volume in Women at Risk for Placental Vascular Diseases: A Monocentric Prospective Study.

Authors:  Cécile Fanget; Céline Chauleur; Amandine Stadler; Emilie Presles; Marie-Noëlle Varlet; Jean-Christophe Gris; Tiphaine Raia-Barjat
Journal:  PLoS One       Date:  2016-06-13       Impact factor: 3.240

9.  Uterine and placental blood flow indexes and antinuclear autoantibodies in unexplained recurrent pregnancy loss: should they be investigated in pregnancy as correlated potential factors? A retrospective study.

Authors:  Valentina Bruno; Carlo Ticconi; Federica Martelli; Marzia Nuccetelli; Maria Vittoria Capogna; Roberto Sorge; Emilio Piccione; Adalgisa Pietropolli
Journal:  BMC Pregnancy Childbirth       Date:  2020-01-20       Impact factor: 3.007

  9 in total