Literature DB >> 17916318

Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas.

Carlos Souza1, Duc H Tran, Jane Loman, Simon K Law, Anne L Coleman, Joseph Caprioli.   

Abstract

PURPOSE: To evaluate the long-term efficacy of intraocular pressure (IOP) reduction and complications of Ahmed glaucoma valve (AGV) implantation (New World Medical, Inc, Rancho Cucamonga, California, USA) in refractory glaucoma.
DESIGN: Retrospective cohort study.
METHODS: Retrospective medical records from 64 patients (78 eyes) with refractory glaucoma who underwent AGV implantation with a minimum of three years of follow-up were reviewed. Data regarding age, gender, race, eye laterality, specific glaucoma diagnosis, best-corrected visual acuity (BCVA), number of medications, IOP, visual fields, surgical complications, and follow-up interval were collected from all visits and were analyzed. The primary outcome measure was cumulative probability of success defined as IOP of less than 21 mm Hg and of 5 mm Hg or more with a minimum of 15% reduction from baseline IOP, without additional glaucoma surgery or loss of light perception. Secondary outcomes included IOP and number of medications at three, six, 12, 24, 36, 48, and 60 months after surgery, surgical complications, and final BCVA.
RESULTS: The cumulative probability of success was 80% and 49% at one and five years, respectively. IOP was reduced from a mean of 30.4 +/- 10.7 mm Hg to 17.0 +/- 5.0 mm Hg at 12 months and 15.9 +/- 3.0 mm Hg at 60 months (P < .001). The number of medications decreased from 3.2 +/- 1.0 medications at baseline to 1.6 +/- 0.4 at 12 months and 2.1 +/- 0.2 at 60 months (P < .001). Prior glaucoma surgery and the silicone type of AGV were statistically significant risk factors for failure (P < .001).
CONCLUSIONS: Approximately 50% of single-plate AGV implantations in refractory glaucoma were considered successful after five years of follow-up. Prior glaucoma surgery was a statistically significant risk factor for failure.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17916318     DOI: 10.1016/j.ajo.2007.07.035

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  44 in total

1.  Low-cost rapid prototyping of liquid crystal polymer based magnetic microactuators for glaucoma drainage devices.

Authors:  Simon John
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

Review 2.  Aqueous shunts for glaucoma.

Authors:  Victoria L Tseng; Anne L Coleman; Melinda Y Chang; Joseph Caprioli
Journal:  Cochrane Database Syst Rev       Date:  2017-07-28

3.  Can topical ketorolac 0.5% improve the function of Ahmed® glaucoma drainage devices?

Authors:  Garrett R Scott; Jennifer S Weizer; Sayoko E Moroi; Christina A Bruno; David C Musch; Leslie M Niziol; Paul P Lee; Joshua D Stein
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2011-03-31

4.  Clinical outcomes of Ahmed glaucoma valve in anterior chamber versus ciliary sulcus.

Authors:  A Bayer; M Önol
Journal:  Eye (Lond)       Date:  2016-12-16       Impact factor: 3.775

5.  Role of trabeculectomy in advanced glaucoma: Whether we stand to consider it a bane or a boon today?

Authors:  Harinder Singh Sethi; Mayuresh P Naik; Komal Saluja
Journal:  Int Ophthalmol       Date:  2017-12-26       Impact factor: 2.031

6.  Long-term success of ahmed glaucoma valve in refractory glaucoma.

Authors:  Mahmut Kaya; Zeynep Ozbek; Aylın Yaman; Ismet Durak
Journal:  Int J Ophthalmol       Date:  2012-02-18       Impact factor: 1.779

7.  Posterior migration of Ahmed glaucoma valve tube in a patient with Reiger anomaly: a case report.

Authors:  Vishnu S Gupta; Harinder S Sethi; Malvika Gupta; Anuj Mehta; Shivram Singh; Pankaj Yadav; K P S Malik
Journal:  BMC Ophthalmol       Date:  2010-09-17       Impact factor: 2.209

8.  Outcomes of Ahmed valve surgery for refractory glaucoma in Dhahran, Saudi Arabia.

Authors:  Tariq Alasbali; Abdullah Ali Alghamdi; Rajiv Khandekar
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

9.  The Ahmed glaucoma valve in neovascular glaucoma (An AOS Thesis).

Authors:  Peter A Netland
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

10.  Long-term results of Ahmed glaucoma valve implantation in Egyptian population.

Authors:  Eman Elhefney; Tharwat Mokbel; Waleed Abou Samra; Hanem Kishk; Tarek Mohsen; Amr El-Kannishy
Journal:  Int J Ophthalmol       Date:  2018-03-18       Impact factor: 1.779

View more