Literature DB >> 17914862

Novel orbital shake bioreactors for transient production of CHO derived IgGs.

Matthieu Stettler1, Xiaowei Zhang, David L Hacker, Maria De Jesus, Florian M Wurm.   

Abstract

Large-scale transient gene expression in mammalian cells is being developed for the rapid production of recombinant proteins for biochemical and preclinical studies. Here, the scalability of transient production of a recombinant human antibody in Chinese hamster ovary (CHO) cells was demonstrated in orbitally shaken disposable bioreactors at scales from 50 mL to 50 L. First, a small-scale multiparameter approach was developed to optimize the poly(ethylenimine)-mediated transfection in 50 mL shake tubes. This study confirmed the benefit, both in terms of extended cell culture viability and increased product yield, of mild hypothermic cultivation conditions for transient gene expression in CHO cells. Second, the scalability of the process was demonstrated in disposable shake bioreactors having nominal volumes of 5, 20, and 50 L with final antibody yields between 30 and 60 mg L(-1). Thus, the combination of transient gene expression with disposable shake bioreactors allows for rapid and cost-effective production of recombinant proteins in CHO cells.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17914862     DOI: 10.1021/bp070219i

Source DB:  PubMed          Journal:  Biotechnol Prog        ISSN: 1520-6033


  7 in total

1.  The need for innovation in biomanufacturing.

Authors:  Uwe Gottschalk; Kurt Brorson; Abhinav A Shukla
Journal:  Nat Biotechnol       Date:  2012-06-07       Impact factor: 54.908

2.  Environmental parameters influence non-viral transfection of human mesenchymal stem cells for tissue engineering applications.

Authors:  William J King; Nicholas A Kouris; Siyoung Choi; Brenda M Ogle; William L Murphy
Journal:  Cell Tissue Res       Date:  2012-01-26       Impact factor: 5.249

3.  Enhanced transient recombinant protein production in CHO cells through the co-transfection of the product gene with Bcl-xL.

Authors:  Matthew P Zustiak; Lisa Jose; Yueqing Xie; Jianwei Zhu; Michael J Betenbaugh
Journal:  Biotechnol J       Date:  2014-05-08       Impact factor: 4.677

4.  Effect of baffle structure on flow field characteristics of orbitally shaken bioreactor.

Authors:  Zhiming Lu; Chengtuo Li; Liangqi Fei; Hongliang Zhang; Yuhui Pan
Journal:  Bioprocess Biosyst Eng       Date:  2020-11-16       Impact factor: 3.210

5.  Optimizing the transient transfection process of HEK-293 suspension cells for protein production by nucleotide ratio monitoring.

Authors:  Maria de Los Milagros Bassani Molinas; Christiane Beer; Friedemann Hesse; Manfred Wirth; Roland Wagner
Journal:  Cytotechnology       Date:  2013-06-18       Impact factor: 2.058

6.  Continuous influenza virus production in a tubular bioreactor system provides stable titers and avoids the "von Magnus effect".

Authors:  Felipe Tapia; Daniel Wohlfarth; Volker Sandig; Ingo Jordan; Yvonne Genzel; Udo Reichl
Journal:  PLoS One       Date:  2019-11-05       Impact factor: 3.240

7.  Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale.

Authors:  Wolf Klöckner; Riad Gacem; Tibor Anderlei; Nicole Raven; Stefan Schillberg; Clemens Lattermann; Jochen Büchs
Journal:  J Biol Eng       Date:  2013-12-02       Impact factor: 4.355

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.