Literature DB >> 17913487

Real-time monitoring of adhesion and aggregation of platelets using thickness shear mode (TSM) sensor.

E Ergezen1, M Appel, P Shah, J Y Kresh, R M Lec, D M Wootton.   

Abstract

Hemostasis is required to maintain vascular system integrity, but thrombosis, formation of a clot in a blood vessel, is one of the largest causes of morbidity and mortality in the industrialized world. Novel clinical and research tools for characterizing the hemostatic system are of continued interest, and the object of this research is to test the hypothesis that clinically relevant platelet function can be monitored using an electromechanical sensor. A piezoelectric thickness shear mode (TSM) biosensor coated with collagen-I fibers to promote platelet activation and adhesion was developed and tested for sensitivity to detect these primary events. Magnitude and frequency response of the sensor were monitored under static conditions at 37 degrees C, using platelet-rich plasma (PRP), and PRP with adenosine diphosphate (ADP), a clinical aggregation inhibitor (abciximab), or a collagen binding inhibitor. Sensors loaded with PRP exhibited a 3-stage response; no significant change in response for the first 20 min (Stage-1), followed by a larger drop in response (Stage-2) and subsequently, response gradually increased (Stage-3). Exogenous ADP stimulated an immediate Stage-2 response, while abciximab delayed and reduced the magnitude change of Stage-2. In the presence of collagen inhibitor, Stage-2 response was similar to that of control but was delayed by an additional 20 min. The obtained results, supported by epifluorescence and complementary SEM studies, demonstrated the selective sensitivity of TSM electromechanical biosensors to monitor platelet function and inhibition, particularly aggregation.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17913487     DOI: 10.1016/j.bios.2007.05.009

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Development of recombinant Aleuria aurantia lectins with altered binding specificities to fucosylated glycans.

Authors:  Patrick R Romano; Andrew Mackay; Minh Vong; Johann DeSa; Anne Lamontagne; Mary Ann Comunale; Julie Hafner; Timothy Block; Ryszard Lec; Anand Mehta
Journal:  Biochem Biophys Res Commun       Date:  2011-09-14       Impact factor: 3.575

2.  Synchronized cell attachment triggered by photo-activatable adhesive ligands allows QCM-based detection of early integrin binding.

Authors:  Jagoba Iturri; Luis García-Fernández; Ute Reuning; Andrés J García; Aránzazu del Campo; Marcelo J Salierno
Journal:  Sci Rep       Date:  2015-03-31       Impact factor: 4.379

3.  Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods.

Authors:  Stephanie Oberfrank; Hartmut Drechsel; Stefan Sinn; Hinnak Northoff; Frank K Gehring
Journal:  Sensors (Basel)       Date:  2016-02-24       Impact factor: 3.576

Review 4.  Microfluidic-Based Multi-Organ Platforms for Drug Discovery.

Authors:  Ahmad Rezaei Kolahchi; Nima Khadem Mohtaram; Hassan Pezeshgi Modarres; Mohammad Hossein Mohammadi; Armin Geraili; Parya Jafari; Mohsen Akbari; Amir Sanati-Nezhad
Journal:  Micromachines (Basel)       Date:  2016-09-08       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.