Standardized analyses of correction of astigmatism with the visian toric phakic implantable collamer lens.

Donald R Sanders1, Edwin J Sarver.   

Abstract

PURPOSE: To demonstrate the methodology described by the American National Standards Institute (ANSI) Standard Subcommittee on Astigmatism Analysis reporting a standardized method of presenting astigmatism data by laser systems that reshape the cornea also applies to toric phakic intraocular lens (IOL) data.
METHODS: The U.S. Food and Drug Administration trial of the Visian Toric Implantable Collamer Lens comprised 210 eyes of 124 study patients. The mean preoperative manifest refraction spherical equivalent for the study cohort was -9.36 +/- 2.66 diopters (D) (range: -19.50 to -2.38 D). The mean preoperative manifest refractive cylinder was 1.94 +/- 0.84 D (range: 1.00 to 4.00 D).
RESULTS: Data were arrayed using the 11 tables and 4 figures suggested in the Subcommittee paper. Interpretation of the data from a toric phakic IOL study was similar to that of laser refractive procedures. The addition of a table of manifest refractive cylinder (in the spectacle plane) over time, which provides a direct clinical measure of clinical efficacy, is suggested. Mean postoperative manifest refractive cylinder was 0.51 +/- 0.48 D (range: 0 to 3.00 D) with 65.6% of eyes having < or = 0.50 D of refractive cylinder at 12 months. A table of observed stability of the toric phakic IOL orientation within the eye obtained by slit-lamp examination also is recommended, which is a useful table not applicable in laser refractive procedures.
CONCLUSIONS: The data presented demonstrate that the methodology developed by the ANSI Standard Subcommittee on Astigmatism Analysis, with some minor additions, accurately characterizes the efficacy of toric phakic IOLs in treating astigmatism.

Entities:  

Mesh:

Year:  2007        PMID: 17912934     DOI: 10.3928/1081-597X-20070901-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Accuracy of corneal astigmatism correction with two Barrett Toric calculation methods.

Authors:  Jun Yang; Hong Zhang; Xiao-Tong Yang; Fang Tian; Shao-Zhen Zhao
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

Review 2.  [Toric phakic intraocular lenses].

Authors:  H B Dick; S E Buchner
Journal:  Ophthalmologe       Date:  2007-12       Impact factor: 1.059

3.  Spontaneous Rotation of a Toric Implantable Collamer Lens.

Authors:  Alejandro Navas; Mayeli Muñoz-Ocampo; Enrique O Graue-Hernández; Arturo Gómez-Bastar; Tito Ramirez-Luquín
Journal:  Case Rep Ophthalmol       Date:  2010-11-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.