Literature DB >> 17910697

Improved correction of axial geometrical distortion in index-mismatched fluorescent confocal microscopic images using high-aperture objective lenses.

H J van Elburg1, L C Kuypers, W F Decraemer, J J J Dirckx.   

Abstract

Extracting quantitative data from microscopic volume images is straightforward when the refractive indices of the immersion medium and the mounting medium are equal. The readings of the position of the specimen stage can be directly used to measure depth and width. Imperfectly matched immersion and mounting media result in axial geometrical distortion. Linear correction of the axial distortion using the paraxial estimate of the axial scaling factor yields results that may differ as much as 4% from the actual values. From calculations based on a theoretical expression of the 3-D point-spread function in the focal region of a high-aperture microscope focussing into a mismatched mounting medium, we derived axial scaling factors that result in quantitative results accurate to better than 1%. From a non-linear correction procedure, an improved formula for the paraxial estimate of the axial scaling factor is derived.

Year:  2007        PMID: 17910697     DOI: 10.1111/j.1365-2818.2007.01822.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  5 in total

1.  Measurement of the thickness and volume of adherent cells using transmission-through-dye microscopy.

Authors:  Jennifer L Gregg; Karen M McGuire; Daniel C Focht; Michael A Model
Journal:  Pflugers Arch       Date:  2010-08-19       Impact factor: 3.657

Review 2.  Calcific aortic valve stenosis: methods, models, and mechanisms.

Authors:  Jordan D Miller; Robert M Weiss; Donald D Heistad
Journal:  Circ Res       Date:  2011-05-27       Impact factor: 17.367

3.  Uptake, efflux, and mass transfer coefficient of fluorescent PAMAM dendrimers into pancreatic cancer cells.

Authors:  Armin W Opitz; Kirk J Czymmek; Eric Wickstrom; Norman J Wagner
Journal:  Biochim Biophys Acta       Date:  2012-09-26

4.  Fluorescent nuclear track detectors for alpha radiation microdosimetry.

Authors:  J J M Kouwenberg; H T Wolterbeek; A G Denkova; A J J Bos
Journal:  Radiat Oncol       Date:  2018-06-07       Impact factor: 3.481

5.  A method for direct imaging of x-z cross-sections of fluorescent samples.

Authors:  A Katiyar; J D Antani; B P McKee; R Gupta; P P Lele; T P Lele
Journal:  J Microsc       Date:  2020-10-19       Impact factor: 1.758

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.