Literature DB >> 17910041

Utility of consecutive repeat HIT ELISA testing for heparin-induced thrombocytopenia.

Maren Chan1, Elizabeth Malynn, Beth Shaz, Lynne Uhl.   

Abstract

Heparin-induced thrombocytopenia (HIT) is a serious complication of heparin therapy. Limited data are available regarding repeat HIT antibody testing after an initial negative test. We conducted a retrospective study to determine the utility of repeat testing. Heparin antibodies were detected using the GTI-PF4 enzyme-linked immunoabsorbent assay, ELISA (GTI Diagnostics, Waukesha, WI). Patients (n = 137) were assigned to one of three groups based upon the initial negative test optical density (OD) range of low = 0-0.132, medium = 0.133-0.267, and high = 0.268-0.399. A pretest clinical score was retrospectively determined using the "4T's" (Thrombocytopenia, Timing of platelet fall, Thrombosis, and the absence of oTher causes of thrombocytopenia). A subsequent positive ELISA was found in 16% (22/137) of patients who underwent repeat testing. Most of these patients had a low pretest clinical score (62%). Four patients had an interval change in the pretest score between the initial negative and subsequent positive tests. Only these four patients developed HIT with thrombosis (HITT). Eighty percent of patients with a high initial negative test OD value had a positive ELISA on repeat testing; however, the initial negative test OD value could not predict whether a patient developed HITT. In contrast, an increase in the pretest clinical probability between initial and repeat testing better predicted HITT. Consecutive repeat ELISA testing for heparin antibodies may be warranted in patients with an increase in their pretest clinical score after an initial negative test as an adjunct to confirm the diagnosis of HIT. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 17910041     DOI: 10.1002/ajh.21074

Source DB:  PubMed          Journal:  Am J Hematol        ISSN: 0361-8609            Impact factor:   10.047


  3 in total

Review 1.  Heparin-induced thrombocytopenia during extracorporeal life support: incidence, management and outcomes.

Authors:  Jae Hwan Choi; Jessica G Y Luc; Matthew P Weber; Haritha G Reddy; Elizabeth J Maynes; Avijit K Deb; Louis E Samuels; Rohinton J Morris; H Todd Massey; Antonio Loforte; Vakhtang Tchantchaleishvili
Journal:  Ann Cardiothorac Surg       Date:  2019-01

2.  False-Negative Platelet Factor 4 Antibodies and Serotonin Release Assay and the Utility of Repeat Testing in the Diagnosis of Heparin-Induced Thrombocytopenia and Thrombosis.

Authors:  Tarig Omer; Naresh Mullaguri; Pravin George; Christopher R Newey
Journal:  Case Rep Hematol       Date:  2019-01-08

Review 3.  Heparin-induced thrombocytopenia (HIT): Identification and treatment pathways.

Authors:  Mahmoud Fathi
Journal:  Glob Cardiol Sci Pract       Date:  2018-06-30
  3 in total