BACKGROUND/
PURPOSE: In recent years, increasing use of injectable resorbable fillings has been reported for facial wrinkle treatment. However, the physiological processes involved such as the localization and subsequent diffusion of the injected product in skin tissues are poorly documented. This may be noninvasively achieved using quantitative magnetic resonance imaging (MRI), which is duly presented in this pilot study.
METHODS: Hyaluronic acid (HA) was injected intradermally in the forearm of a young male volunteer. High-resolution MRI scans using a surface antenna were performed just after injection, and after 2, 4 and 9 months. Morphological images were compared with transverse relaxation time (T(2)) images computed from a pixel-by-pixel analysis.
RESULTS: On high-resolution morphological MR images the HA injection is barely visible, but with quantitative MRI the zone of injection is clearly seen. This is due to HA having a distinctly different transverse relaxation time, T(2) approximately 600 ms, compared with dermal and hypodermal tissues, 35 and 80 ms, respectively.
CONCLUSION: These preliminary results demonstrate the ability of the T(2) images for in vivo visualization of the filler agent and also for characterization of tissue modifications. In addition, the diffusion and progressive degradation of the filler agent can be monitored by T(2) measurements over time.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17908189     DOI: 10.1111/j.1600-0846.2007.00241.x

Source DB:  PubMed          Journal:  Skin Res Technol        ISSN: 0909-752X            Impact factor:   2.365


  9 in total

Review 1.  Imaging features of midface injectable fillers and associated complications.

Authors:  D T Ginat; C J Schatz
Journal:  AJNR Am J Neuroradiol       Date:  2012-07-26       Impact factor: 3.825

2.  Visualization of mouse pancreas architecture using MR microscopy.

Authors:  Paul J Grippo; Palamadai N Venkatasubramanian; Richard H Knop; Daniel M Heiferman; Gheorghe Iordanescu; Laleh G Melstrom; Kevin Adrian; Morgan R Barron; David J Bentrem; Alice M Wyrwicz
Journal:  Am J Pathol       Date:  2011-05-31       Impact factor: 4.307

3.  MRI in the evaluation of facial dermal fillers in normal and complicated cases.

Authors:  Marco Di Girolamo; Mauro Mattei; Alberto Signore; Francesca Romana Grippaudo
Journal:  Eur Radiol       Date:  2014-12-05       Impact factor: 5.315

4.  Duration of wrinkle correction following repeat treatment with Juvéderm hyaluronic acid fillers.

Authors:  Stacy R Smith; Derek Jones; Jane A Thomas; Diane K Murphy; Frederick C Beddingfield
Journal:  Arch Dermatol Res       Date:  2010-10-09       Impact factor: 3.017

5.  Adipose segmentation in small animals at 7T: a preliminary study.

Authors:  Yang Tang; Susan Lee; Marvin D Nelson; Simerly Richard; Rex A Moats
Journal:  BMC Genomics       Date:  2010-12-01       Impact factor: 3.969

6.  Complete biodegradable nature of calcium hydroxylapatite after injection for malar enhancement: an MRI study.

Authors:  Tatjana Pavicic
Journal:  Clin Cosmet Investig Dermatol       Date:  2015-02-09

7.  Long-Term Follow-Up of Longevity and Diffusion Pattern of Hyaluronic Acid in Nasolabial Fold Correction through High-Frequency Ultrasound.

Authors:  Ju Qiao; Qian-Nan Jia; Hong-Zhong Jin; Feng Li; Chun-Xia He; Jun Yang; Ya-Gang Zuo; Lan-Qin Fu
Journal:  Plast Reconstr Surg       Date:  2019-08       Impact factor: 4.730

8.  Semipermanent volumization by an absorbable filler: onlay injection technique to the bone.

Authors:  Takanobu Mashiko; Harushi Mori; Harunosuke Kato; Kentaro Doi; Shinichiro Kuno; Kahori Kinoshita; Akira Kunimatsu; Kuni Ohtomo; Kotaro Yoshimura
Journal:  Plast Reconstr Surg Glob Open       Date:  2013-05-07

Review 9.  Injectable facial fillers: imaging features, complications, and diagnostic pitfalls at MRI and PET CT.

Authors:  Pravin Mundada; Romain Kohler; Sana Boudabbous; Laurence Toutous Trellu; Alexandra Platon; Minerva Becker
Journal:  Insights Imaging       Date:  2017-10-04
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.