Literature DB >> 17906778

Efficacy of the FEV1/FEV6 ratio compared to the FEV1/FVC ratio for the diagnosis of airway obstruction in subjects aged 40 years or over.

F W Rosa1, R Perez-Padilla, A Camelier, O A Nascimento, A M B Menezes, J R Jardim.   

Abstract

The present cross-sectional, population-based study was designed to evaluate the performance of the FEV1/FEV6 ratio for the detection of airway-obstructed subjects compared to the FEV1/FVC <0.70 fixed ratio test, as well as the lower limit of normality (LLN) for 1000 subjects (3)40 years of age in the metropolitan area of São Paulo, SP, Brazil. After the exclusion of 37 (3.7%) spirometries, a total of 963 pre-bronchodilator (BD) and 918 post-BD curves were constructed. The majority of the post-BD curves (93.1%) were of very good quality and achieved grade A (762 curves) or B (93 curves). The FEV1/FEV6 and FEV1/FVC ratios were highly correlated (r(2) = 0.92, P < 0.000). Two receiver operator characteristic curves were constructed in order to express the imbalance between the sensitivity and specificity of the FEV1/FEV6 ratio compared to two FEV1/FVC cut-off points for airway obstruction: equal to 70 (area under the curve = 0.98, P < 0.0001) and the LLN (area under the curve = 0.97, P < 0.0001), in the post-BD curves. According to an FEV1/FVC <0.70, the cut-off point for the FEV1/FEV6 ratio with the highest sum for sensitivity and specificity was 0.75. The FEV1/FEV6 ratio can be considered to be a good alternative to the FEV1/FVC ratio for the diagnosis of airway obstruction, both using a fixed cut-off point or below the LLN as reference. The FEV1/FEV6 ratio has the additional advantage of being an easier maneuver for the subjects and for the lung function technicians, providing a higher reproducibility than traditional spirometry maneuvers.

Entities:  

Mesh:

Year:  2007        PMID: 17906778     DOI: 10.1590/s0100-879x2006005000182

Source DB:  PubMed          Journal:  Braz J Med Biol Res        ISSN: 0100-879X            Impact factor:   2.590


  17 in total

1.  On-site screening of farming-induced chronic obstructive pulmonary disease with the use of an electronic mini-spirometer: results of a pilot study in Brittany, France.

Authors:  Stephane Jouneau; Arnaud Boché; Graziella Brinchault; Kristina Fekete; Stephanie Guillot; Sahar Bayat; Benoit Desrues
Journal:  Int Arch Occup Environ Health       Date:  2011-10-11       Impact factor: 3.015

2.  FEV(6) as screening tool in spirometric diagnosis of obstructive airway disease.

Authors:  P Adithya Malolan; Vishak Acharya; B Unnikrishnan
Journal:  Lung India       Date:  2010-04

3.  Comparison of spirometry criteria for the diagnosis of COPD: results from the BOLD study.

Authors:  W M Vollmer; Thorn Gíslason; P Burney; P L Enright; A Gulsvik; A Kocabas; A S Buist
Journal:  Eur Respir J       Date:  2009-05-21       Impact factor: 16.671

4.  VitalQPlus: a potential screening tool for early diagnosis of COPD.

Authors:  Chee Fai Sui; Long Chiau Ming; Chin Fen Neoh; Baharudin Ibrahim
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2015-08-11

5.  Efficient screening for COPD using three steps: a cross-sectional study in Mexico City.

Authors:  Francisco Franco-Marina; Rosario Fernandez-Plata; Luis Torre-Bouscoulet; Cecilia García-Sancho; Elisa Sanchez-Gallen; David Martinez; Rogelio Perez-Padilla
Journal:  NPJ Prim Care Respir Med       Date:  2014-05-20       Impact factor: 2.871

6.  Validity of the Handheld Expiratory Flowmeter for COPD Screening in the Primary Care Setting of China.

Authors:  Shuyun Chen; Xiaochen Li; Zihui Wang; Yumin Zhou; Dongxing Zhao; Zhuxiang Zhao; Sha Liu; Pixin Ran
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2021-07-08

7.  Fixed Cut-Off for FEV1/FEV6 and FEV6 in Detection of Obstructive and Restrictive Patterns.

Authors:  Rokhsareh Aghili; Maryam Kia; Alipasha Meysamie; Seyed Mojtaba Aghili; Omalbanin Paknejad
Journal:  Iran Red Crescent Med J       Date:  2013-02-05       Impact factor: 0.611

8.  Design, rationale, and baseline demographics of SEARCH I: a prospective cluster-randomized study.

Authors:  Frank Albers; Asif Shaikh; Ahmar Iqbal
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2012-07-11

9.  Reliability of FEV1/FEV6 to diagnose airflow obstruction compared with FEV1/FVC: the PLATINO longitudinal study.

Authors:  Rogelio Perez-Padilla; Fernando C Wehrmeister; Bartolome R Celli; Maria Victorina Lopez-Varela; Maria Montes de Oca; Adriana Muiño; Carlos Talamo; Jose R Jardim; Gonzalo Valdivia; Carmen Lisboa; Ana Maria B Menezes
Journal:  PLoS One       Date:  2013-08-01       Impact factor: 3.240

10.  Detection of airflow limitation using a handheld spirometer in a primary care setting.

Authors:  Siew-Mooi Ching; Yong-Kek Pang; David Price; Ai-Theng Cheong; Ping-Yein Lee; Ismail Irmi; Hassan Faezah; Ismail Ruhaini; Yook-Chin Chia
Journal:  Respirology       Date:  2014-04-07       Impact factor: 6.424

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.