Literature DB >> 17905268

Global end-diastolic volume as a variable of fluid responsiveness during acute changing loading conditions.

Jochen Renner1, Mathias Gruenewald, Philip Brand, Markus Steinfath, Jens Scholz, Georg Lutter, Berthold Bein.   

Abstract

OBJECTIVE: Dynamic variables of preload such as stroke volume variation (SVV) have been shown to be good predictors of fluid responsiveness. They are, however, not applicable during spontaneous breathing and cardiac arrhythmias. Volumetric variables of preload, such as global end-diastolic volume (GEDV) and left ventricular end-diastolic area (LVEDA), might be alternative variables of preload to guide fluid administration. Therefore, the present study was designed to evaluate whether GEDV and LVEDA are suitable parameters of preload and fluid responsiveness during rapidly changing loading conditions.
DESIGN: Prospective animal study.
SETTING: Animal laboratory of a university hospital. PARTICIPANTS: Fourteen pigs.
INTERVENTIONS: The pigs were studied during changing loading conditions as follows: normovolemia, after removal of 500 mL of blood, and after retransfusion plus an additional 500 mL of 6% hydroxyethyl starch. Cardiac output (CO), stroke volume index (SVI), and GEDV were obtained by transpulmonary thermodilution. Additionally, CO, SVI, and SVV were monitored continuously by pulse-contour analysis.
MEASUREMENTS AND MAIN RESULTS: Measurements of hemodynamic variables at each experimental stage were obtained after a period of stabilization. GEDV and LVEDA but not SVV, central venous pressure, and pulmonary capillary wedge pressure accurately reflected rapid changes in preload. When analyzing the correlation of percentage change of preload variables with the percentage change of SVI after fluid resuscitation, only SVV and GEDV showed a significant correlation with fluid responsiveness.
CONCLUSIONS: In this animal model, GEDV and LVEDA were superior to SVV in accurately reflecting hemorrhage. However, GEDV and SVV but not LVEDA were suitable to predict fluid responsiveness.

Entities:  

Mesh:

Year:  2007        PMID: 17905268     DOI: 10.1053/j.jvca.2007.05.006

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  11 in total

1.  Can non-invasive measurements aid clinical assessment of volume in patients with cirrhosis?

Authors:  Andrew Davenport; Banwari Argawal; Gavin Wright; Konstantinos Mantzoukis; Rumyana Dimitrova; Joseph Davar; Panayota Vasianopoulou; Andrew K Burroughs
Journal:  World J Hepatol       Date:  2013-08-27

Review 2.  [Haemodynamic monitoring in the perioperative phase. Available systems, practical application and clinical data].

Authors:  U Wittkowski; C Spies; M Sander; J Erb; A Feldheiser; C von Heymann
Journal:  Anaesthesist       Date:  2009-08       Impact factor: 1.041

3.  Femoral indicator injection for transpulmonary thermodilution using the EV1000/VolumeView(®): do the same criteria apply as for the PiCCO(®)?

Authors:  Wolfgang Huber; Veit Phillip; Josef Höllthaler; Caroline Schultheiss; Bernd Saugel; Roland M Schmid
Journal:  J Zhejiang Univ Sci B       Date:  2016-07       Impact factor: 3.066

4.  Transpulmonary thermodilution using femoral indicator injection: a prospective trial in patients with a femoral and a jugular central venous catheter.

Authors:  Bernd Saugel; Andreas Umgelter; Tibor Schuster; Veit Phillip; Roland M Schmid; Wolfgang Huber
Journal:  Crit Care       Date:  2010-05-25       Impact factor: 9.097

5.  Transoesophageal echocardiography for monitoring liver surgery: data from a pilot study.

Authors:  Filipe Pissarra; Antonio Oliveira; Paulo Marcelino
Journal:  Cardiol Res Pract       Date:  2012-04-30       Impact factor: 1.866

6.  Systemic Capillary Leak Syndrome associated with hypovolemic shock and compartment syndrome. Use of transpulmonary thermodilution technique for volume management.

Authors:  Bernd Saugel; Andreas Umgelter; Friedrich Martin; Veit Phillip; Roland M Schmid; Wolfgang Huber
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2010-07-05       Impact factor: 2.953

7.  Computed tomography to estimate cardiac preload and extravascular lung water. A retrospective analysis in critically ill patients.

Authors:  Bernd Saugel; Konstantin Holzapfel; Jens Stollfuss; Tibor Schuster; Veit Phillip; Caroline Schultheiss; Roland M Schmid; Wolfgang Huber
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2011-05-23       Impact factor: 2.953

8.  Relationship between Abdominal Pressure, Pulmonary Compliance, and Cardiac Preload in a Porcine Model.

Authors:  Joost Wauters; Piet Claus; Nathalie Brosens; Myles McLaughlin; Greet Hermans; Manu Malbrain; Alexander Wilmer
Journal:  Crit Care Res Pract       Date:  2012-02-20

Review 9.  Goal-directed therapy in intraoperative fluid and hemodynamic management.

Authors:  Maria Cristina Gutierrez; Peter G Moore; Hong Liu
Journal:  J Biomed Res       Date:  2013-03-10

10.  Fluid loading and norepinephrine infusion mask the left ventricular preload decrease induced by pleural effusion.

Authors:  Kristian Borup Wemmelund; Viktor Kromann Ringgård; Simon Tilma Vistisen; Janus Adler Hyldebrandt; Erik Sloth; Peter Juhl-Olsen
Journal:  Intensive Care Med Exp       Date:  2017-09-11
View more