Literature DB >> 1790361

Simultaneous acquisition of phase-contrast angiograms and stationary-tissue images with Hadamard encoding of flow-induced phase shifts.

C L Dumoulin1, S P Souza, R D Darrow, N J Pelc, W J Adams, S A Ash.   

Abstract

A technique for the simultaneous acquisition of three-dimensional phase-contrast angiograms and stationary-tissue images is described. Hadamard multiplexed encoding of flow information permits image acquisition times that are a third shorter than those of previous phase-contrast methods. The encoding scheme described also enables differentiation of flow-induced phase shifts from phase shifts due to resonance offset conditions such as field inhomogeneities and chemical shift. Display strategies that combine this phase information with the flow image are described.

Mesh:

Year:  1991        PMID: 1790361     DOI: 10.1002/jmri.1880010403

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  12 in total

1.  PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography.

Authors:  Tianliang Gu; Frank R Korosec; Walter F Block; Sean B Fain; Quill Turk; Darren Lum; Yong Zhou; Thomas M Grist; Victor Haughton; Charles A Mistretta
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

2.  Limits to flow detection in phase contrast MRI.

Authors:  Nathan H Williamson; Michal E Komlosh; Dan Benjamini; Peter J Basser
Journal:  J Magn Reson Open       Date:  2020-07-22

3.  Shared velocity encoding: a method to improve the temporal resolution of phase-contrast velocity measurements.

Authors:  Hung-Yu Lin; Jacob A Bender; Yu Ding; Yiu-Cho Chung; Alice M Hinton; Michael L Pennell; Kevin K Whitehead; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

4.  4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis.

Authors:  M J Negahdar; Mo Kadbi; Michael Kendrick; Marcus F Stoddard; Amir A Amini
Journal:  Magn Reson Med       Date:  2015-04-27       Impact factor: 4.668

5.  Improved SNR in phase contrast velocimetry with five-point balanced flow encoding.

Authors:  Kevin M Johnson; Michael Markl
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

6.  PC HYPR flow: a technique for rapid imaging of contrast dynamics.

Authors:  Julia V Velikina; Kevin M Johnson; Yijing Wu; Alexey A Samsonov; Patrick Turski; Charles A Mistretta
Journal:  J Magn Reson Imaging       Date:  2010-02       Impact factor: 4.813

7.  Velocity mapping of the aortic flow at 9.4 T in healthy mice and mice with induced heart failure using time-resolved three-dimensional phase-contrast MRI (4D PC MRI).

Authors:  Philipp Rene Bovenkamp; Tobias Brix; Florian Lindemann; Richard Holtmeier; Desiree Abdurrachim; Michael T Kuhlmann; Gustav J Strijkers; Jörg Stypmann; Klaus H Hinrichs; Verena Hoerr
Journal:  MAGMA       Date:  2014-11-08       Impact factor: 2.310

8.  Cardiac 4D phase-contrast CMR at 9.4 T using self-gated ultra-short echo time (UTE) imaging.

Authors:  M Krämer; A G Motaal; K-H Herrmann; B Löffler; J R Reichenbach; G J Strijkers; V Hoerr
Journal:  J Cardiovasc Magn Reson       Date:  2017-03-31       Impact factor: 5.364

Review 9.  4D flow cardiovascular magnetic resonance consensus statement.

Authors:  Petter Dyverfeldt; Malenka Bissell; Alex J Barker; Ann F Bolger; Carl-Johan Carlhäll; Tino Ebbers; Christopher J Francios; Alex Frydrychowicz; Julia Geiger; Daniel Giese; Michael D Hope; Philip J Kilner; Sebastian Kozerke; Saul Myerson; Stefan Neubauer; Oliver Wieben; Michael Markl
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-10       Impact factor: 5.364

10.  Analysis and improvement of motion encoding in magnetic resonance elastography.

Authors:  Christian Guenthner; Jurgen Henk Runge; Ralph Sinkus; Sebastian Kozerke
Journal:  NMR Biomed       Date:  2018-03-30       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.