Literature DB >> 17903514

Device closure of atrial septal defects with the Amplatzer septal occluder: safety and outcome in infants.

Karim A Diab1, Qi-Ling Cao, Emile A Bacha, Ziyad M Hijazi.   

Abstract

OBJECTIVE: Device closure of secundum atrial septal defects is sometimes needed in young children; however, little is known about the safety and outcome of this procedure in infants. In this study, the safety and efficacy of secundum atrial septal defect closure with the Amplatzer septal occluder (AGA Medical Corp, Golden Valley, Minn) was evaluated in patients less than 1 year of age.
METHODS: Between July 1999 and September 2006, atrial septal defect closure with the Amplatzer septal occluder was attempted in 15 infants at our institution. The patients ranged in age from 0.5 to 11.9 months (mean +/- standard deviation; 8.2 +/- 3.7 months) in the percutaneous group and from 2.2 to 3.4 months (2.9 +/- 0.6 months) in the peratrial group. Their weights ranged from 3.8 to 8.3 kg (5.5 +/- 1.7 kg) and from 3.0 to 4.0 kg (3.4 +/- 0.6 kg) in each group, respectively. The indications for atrial septal defect closure were failure to thrive, significant chamber enlargement, hemodynamically significant shunts, and prehepatic transplantation. The size of the defect as measured by intracardiac echocardiography (n = 3) or transesophageal echocardiography (n = 12) ranged from 2.0 to 16 mm (8.0 +/- 4.4 mm).
RESULTS: The pulmonary/systemic flow ratio ranged from 1.0 to 9.0 (2.8 +/- 2.0). The device was successfully placed in 14 of 15 infants. The size of the Amplatzer septal occluder device implanted ranged from 4 to 20 mm (10.1 +/- 4.3 mm). It was percutaneously deployed in 11 of 14 patients and by the hybrid or peratrial approach (open chest off-pump) in 3 of 14 infants. In infants who had a successful attempt (n = 14), the complete closure rates at 24 hours and 1 year were 86% and 100%, respectively. In 3 of 15 infants, minor complications occurred: transient arrhythmias (n = 2) and blood transfusion (n = 1). One patient had a major complication (vascular intimal injury with thrombosis of the inferior vena cava). One patient with Down syndrome died 6 weeks later of progressive pulmonary hypertension. The follow-up time ranged from 0.6 to 6.9 years (3.2 +/- 1.9 years). At follow-up, clinical development and growth improved in all children with failure to thrive, and all ventilator-dependent children could be weaned shortly after closure of the atrial septal defect.
CONCLUSION: Device closure of atrial septal defects is an effective and fairly safe alternative to surgery in infants. Hybrid or peratrial closure is also an alternative to percutaneous closure in the very small infant.

Entities:  

Mesh:

Year:  2007        PMID: 17903514     DOI: 10.1016/j.jtcvs.2007.06.018

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  27 in total

1.  Mechanical support of the left atrial disc during transcatheter closure of large atrial septal defects in children.

Authors:  Dagmar Hohmann; Stephan Schoof; Armin Wessel; Harald Bertram
Journal:  Pediatr Cardiol       Date:  2008-12-04       Impact factor: 1.655

2.  Amplatzer septal occluder and atrioventricular block: A case report and literature review.

Authors:  Ali A Al Akhfash; Abdulrahman Al-Mesned; Majid Al Fayadh
Journal:  J Saudi Heart Assoc       Date:  2013-02-05

3.  Impact of the Amplatzer atrial septal occluder device on left ventricular function in pediatric patients.

Authors:  Biagio Castaldi; Giuseppe Santoro; Giovanni Di Salvo; Gianpiero Gaio; Maria Teresa Palladino; Fabio D'Aiello; Carola Iacono; Giuseppe Pacileo; Raffaele Calabrò; Maria Giovanna Russo
Journal:  Pediatr Cardiol       Date:  2013-04-17       Impact factor: 1.655

4.  Percutaneous atrial septal defect closure in infants and toddlers: predictors of success.

Authors:  Christopher J Petit; Henri Justino; Ricardo H Pignatelli; Matthew A Crystal; William A Payne; Frank F Ing
Journal:  Pediatr Cardiol       Date:  2012-07-18       Impact factor: 1.655

5.  Longitudinal evaluation of P-wave dispersion and P-wave maximum in children after transcatheter device closure of secundum atrial septal defect.

Authors:  Robert Teodoro Grignani; Kim Martin Tolentino; Dimple Dayaram Rajgor; Swee Chye Quek
Journal:  Pediatr Cardiol       Date:  2015-01-28       Impact factor: 1.655

6.  Bronchial compression in an infant with isolated secundum atrial septal defect associated with severe pulmonary arterial hypertension.

Authors:  Sung-Hee Park; So Young Park; Nam Kyun Kim; Su-Jin Park; Han Ki Park; Young Hwan Park; Jae Young Choi
Journal:  Korean J Pediatr       Date:  2012-08-23

7.  Perventricular closure of muscular ventricular septal defects: How do I do it?

Authors:  Karim A Diab; Qi-Ling Cao; Ziyad M Hijazi
Journal:  Ann Pediatr Cardiol       Date:  2008-01

8.  Percutaneous closure of atrial septal defects in spontaneously breathing children under deep sedation: a feasible and safe concept.

Authors:  Andreas Hanslik; Axel Moysich; K Thorsten Laser; Elisabeth Mlczoch; Deniz Kececioglu; Nikolaus A Haas
Journal:  Pediatr Cardiol       Date:  2013-07-30       Impact factor: 1.655

9.  Device closure of secundum atrial septal defects in infants weighing less than 8 kg.

Authors:  Ram N Bishnoi; Allen D Everett; Richard E Ringel; Carl Y Owada; Ralf J Holzer; Joanne L Chisolm; Wolfgang A Radtke; D Scott Lim; John F Rhodes; John D Coulson
Journal:  Pediatr Cardiol       Date:  2014-04-11       Impact factor: 1.655

10.  Anterior Minithoracotomy: a Safe Approach for Surgical ASD Closure & ASD Device Retrieval.

Authors:  Vivek Wadhawa; Chirag Doshi; Manish Hinduja; Pankaj Garg; Kartik Patel; Amit Mishra; Pratik Shah
Journal:  Braz J Cardiovasc Surg       Date:  2017 Jul-Aug
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.