Sequential injection chemiluminescence immunoassay for nonionic surfactants by using magnetic microbeads.

Ruiqi Zhang1, Hizuru Nakajima, Nobuaki Soh, Koji Nakano, Takashi Masadome, Kazumi Nagata, Kazuhira Sakamoto, Toshihiko Imato.   

Abstract

A rapid and sensitive immunoassay based on a sequential injection analysis (SIA) using magnetic microbeads for the determination of alkylphenol polyethoxylates (APnEOs) is described. An SIA system was constructed from a syringe pump, a switching valve, a flow-through type immunoreaction cell equipped with a photon counting unit and a neodymium magnet. Magnetic beads, to which an anti-APnEOs monoclonal antibody was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of the magnetic beads in and from the immunoreaction cell were controlled by means of a neodymium magnet and adjusting the flow of a carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an anti-APnEOs monoclonal antibody immobilized on the magnetic beads with a sample APnEOs and a horseradish peroxidase (HRP)-labeled APnEOs in the same sample solution, and was based on the subsequent chemiluminscence reaction of HRP on the magnetic microbeads with a luminol solution containing hydrogen peroxide and p-iodophenol. The anti-APnEOs antibody was immobilized on the magnetic microbeads by coupling the antibody with the magnetic beads after activation of a carboxylate moiety on the surface of the magnetic beads that had been coated with a polylactic acid film. The antibody immobilized magnetic beads were introduced in the immunoreaction cell and trapped in it by the neodymium magnet, which was equipped beneath the immunoreaction cell. An APnEOs sample solution containing the HRP-labeled APnEOs at a constant concentration, and a luminol solution containing hydrogen peroxide and p-iodophenol were sequentially introduced into the immunoreaction cell, according to an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photon counting unit located at the upper side of the immunoreaction cell by collecting the emitted light with a lens. A typical sigmoidal calibration curve was obtained, when the logarithm of the concentration of APnEOs was plotted against the chemiluminescence intensity as the number of photons in 100 ms using standard APnEOs sample solutions at various concentrations (0-1000 ppb) under optimum conditions. The lower detection limit defined as IC(80) is ca 10 ppb. The time required for analysis is less than 15 min per a sample. The present method was successfully applied to the determination of APnEOs in river water.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17903471     DOI: 10.1016/j.aca.2007.02.052

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases.

Authors:  Harpal Singh; Masayuki Shimojima; Tomomi Shiratori; Le Van An; Masami Sugamata; Ming Yang
Journal:  Sensors (Basel)       Date:  2015-07-08       Impact factor: 3.576

2.  Magnetic poly(2-hydroxyethyl methacrylate) microspheres for affinity purification of monospecific anti-p46 kDa/Myo1C antibodies for early diagnosis of multiple sclerosis patients.

Authors:  Daniel Horák; Helena Hlídková; Yurii Kit; Volodymyr Antonyuk; Severyn Myronovsky; Rostyslav Stoika
Journal:  Biosci Rep       Date:  2017-04-28       Impact factor: 3.840

Review 3.  Tumor Biomarker In-Solution Quantification, Standard Production, and Multiplex Detection.

Authors:  Nicole C Japp; Joshua J Souchek; Aaron R Sasson; Michael A Hollingsworth; Surinder K Batra; Wade M Junker
Journal:  J Immunol Res       Date:  2021-09-01       Impact factor: 4.818

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.