Literature DB >> 17903467

Novel approaches to analysis by flow injection gradient titration.

Marzena Wójtowicz1, Joanna Kozak, Paweł Kościelniak.   

Abstract

Two novel procedures for flow injection gradient titration with the use of a single stock standard solution are proposed. In the multi-point single-line (MP-SL) method the calibration graph is constructed on the basis of a set of standard solutions, which are generated in a standard reservoir and subsequently injected into the titrant. According to the single-point multi-line (SP-ML) procedure the standard solution and a sample are injected into the titrant stream from four loops of different capacities, hence four calibration graphs are able to be constructed and the analytical result is calculated on the basis of a generalized slope of these graphs. Both approaches have been tested on the example of spectrophotometric acid-base titration of hydrochloric and acetic acids with using bromothymol blue and phenolphthalein as indicators, respectively, and sodium hydroxide as a titrant. Under optimized experimental conditions the analytical results of precision less than 1.8 and 2.5% (RSD) and of accuracy less than 3.0 and 5.4% (relative error (RE)) were obtained for MP-SL and SP-ML procedures, respectively, in ranges of 0.0031-0.0631 mol L(-1) for samples of hydrochloric acid and of 0.1680-1.7600 mol L(-1) for samples of acetic acid. The feasibility of both methods was illustrated by applying them to the total acidity determination in vinegar samples with precision lower than 0.5 and 2.9% (RSD) for MP-SL and SP-ML procedures, respectively.

Entities:  

Year:  2007        PMID: 17903467     DOI: 10.1016/j.aca.2007.04.005

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Electrochemical Generation and Detection of Transient Concentration Gradients in Microfluidic Channels. Theoretical and Experimental Investigations.

Authors:  Thomas Abadie; Catherine Sella; Pierre Perrodin; Laurent Thouin
Journal:  Front Chem       Date:  2019-10-24       Impact factor: 5.221

2.  Novel Approach to Automated Flow Titration for the Determination of Fe(III).

Authors:  Joanna Kozak; Justyna Paluch; Marek Kozak; Marta Duracz; Marcin Wieczorek; Paweł Kościelniak
Journal:  Molecules       Date:  2020-03-27       Impact factor: 4.411

3.  Novel Integrated Flow-Based Steam Distillation and Titration System for Determination of Volatile Acidity in Wines.

Authors:  Justyna Paluch; Joanna Kozak; Karolina Mermer; Iwona Molęda; Marcin Wieczorek; Sławomir Kalinowski; Paweł Kościelniak
Journal:  Molecules       Date:  2021-12-18       Impact factor: 4.411

  3 in total