Literature DB >> 17901144

Ovarian volume measurements in mice with high-resolution ultrasonography.

Andrej Lyshchik1, Stephen B Hobbs, Arthur C Fleischer, Dineo Khabele, Deok-Soo Son, John C Gore, Ronald R Price.   

Abstract

OBJECTIVE: The aim of our study was to evaluate the intraobserver and interobserver variability of ovarian volume measurements in mice with high-resolution 2-dimensional ultrasonography (2DUS) and 3-dimensional ultrasonography (3DUS).
METHODS: Ovaries of 10 nude mice were visualized with a small-animal ultrasound scanner and a 40-MHz probe. For each ovary, volume was measured 3 times by 2 independent readers using both 2DUS and 3DUS methods. The 2DUS method used a biplane ellipsoid model. The 3DUS method estimated the volume by integrating 10 to 12 parallel image planes of the ovary after semiautomated outlining of the boundaries. For each type of measurement, intraobserver and interobserver standard error of measurement (SEM) values and minimal detectable volume changes were calculated by analysis of variance.
RESULTS: Two-dimensional ultrasonography showed much poorer reproducibility, with higher absolute intraobserver and interobserver SEM values (0.50 and 0.61 mm3, respectively) than 3DUS (0.20 and 0.35 mm3; P < .01). Relative intraobserver and interobserver SEM values were also much higher for 2DUS (12.20% and 14.88%) than for 3DUS (5.12% and 8.97%; P < .01). The minimal volume changes that could be detected with a 95% confidence level in successive measurements by the same (or different) observers were 33.90% (41.22%) for 2DUS and 14.10% (24.87%) for 3DUS.
CONCLUSIONS: High-resolution 3DUS can provide a reliable tool for noninvasive, longitudinal ovarian volume measurements in mice.

Entities:  

Mesh:

Year:  2007        PMID: 17901144     DOI: 10.7863/jum.2007.26.10.1419

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Ultrasound Molecular Imaging of Angiogenesis Using Vascular Endothelial Growth Factor-Conjugated Microbubbles.

Authors:  Jianjun Wang; Bin Qin; Xucai Chen; William R Wagner; Flordeliza S Villanueva
Journal:  Mol Pharm       Date:  2017-02-15       Impact factor: 4.939

2.  Xenograft and Transgenic Mouse Models of Epithelial Ovarian Cancer and Non Invasive Imaging Modalities to Monitor Ovarian Tumor Growth In situ -Applications in Evaluating Novel Therapeutic Agents.

Authors:  Denise C Connolly; Harvey H Hensley
Journal:  Curr Protoc Pharmacol       Date:  2009-06-01

3.  Complementarity of ultrasound and fluorescence imaging in an orthotopic mouse model of pancreatic cancer.

Authors:  Cynthia S Snyder; Sharmeela Kaushal; Yuko Kono; Hop S Tran Cao; Robert M Hoffman; Michael Bouvet
Journal:  BMC Cancer       Date:  2009-04-08       Impact factor: 4.430

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.