Literature DB >> 17899605

Spin-echo MRI underestimates functional changes in microvascular cerebral blood plasma volume using exogenous contrast agent.

Joseph B Mandeville1, Francisca P Leite, John J A Marota.   

Abstract

While most functional MRI studies using exogenous contrast agent employ gradient-echo (GE) signal, spin echo (SE) imaging would represent an attractive alternative if its detection power were more comparable with GE imaging. This study demonstrates that SE methods systematically underestimate functional changes in microvascular cerebral blood plasma volume (CBV), so that SE detection power in brain tissue cannot match that provided by GE signal. Empirically, the in vivo response of SE-CBV was about 40% smaller than that of GE-CBV in rat brain at low basal values of CBV, a result that is consistent with physics predictions under the simplifying assumption of uniform vessel dilation. However, increasing values of basal CBV were associated with monotonically increasing mean vessel sizes and monotonically decreasing GE to SE ratios of functional changes in CBV (fCBV). This result suggests the presence of large but weakly reactive conduit vessels at high basal values of CBV. Hence, we conclude that GE imaging is the method of choice for functional MRI (fMRI) using exogenous contrast agent in most cases, although SE methods may represent a more spatially linear representation of underlying neural activity that becomes most apparent in regions with high basal CBV, such as the cortical surface.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17899605     DOI: 10.1002/mrm.21380

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

Review 1.  IRON fMRI measurements of CBV and implications for BOLD signal.

Authors:  Joseph B Mandeville
Journal:  Neuroimage       Date:  2012-01-16       Impact factor: 6.556

Review 2.  Data collection and analysis strategies for phMRI.

Authors:  Joseph B Mandeville; Christina H Liu; Wim Vanduffel; John J A Marota; Bruce G Jenkins
Journal:  Neuropharmacology       Date:  2014-03-05       Impact factor: 5.250

3.  CNS animal fMRI in pain and analgesia.

Authors:  David Borsook; Lino Becerra
Journal:  Neurosci Biobehav Rev       Date:  2010-11-30       Impact factor: 8.989

4.  Quantitative pharmacologic MRI in mice.

Authors:  Teodora-Adriana Perles-Barbacaru; Daniel Procissi; Andrey V Demyanenko; Russell E Jacobs
Journal:  NMR Biomed       Date:  2011-07-25       Impact factor: 4.044

5.  In vivo validation of MRI vessel caliber index measurement methods with intravital optical microscopy in a U87 mouse brain tumor model.

Authors:  Christian T Farrar; Walid S Kamoun; Carsten D Ley; Young R Kim; Seon J Kwon; Guangping Dai; Bruce R Rosen; Emmanuelle di Tomaso; Rakesh K Jain; A Gregory Sorensen
Journal:  Neuro Oncol       Date:  2010-01-11       Impact factor: 12.300

Review 6.  Cerebral blood volume MRI with intravascular superparamagnetic iron oxide nanoparticles.

Authors:  Seong-Gi Kim; Noam Harel; Tao Jin; Tae Kim; Phil Lee; Fuqiang Zhao
Journal:  NMR Biomed       Date:  2012-12-04       Impact factor: 4.044

Review 7.  Animal Functional Magnetic Resonance Imaging: Trends and Path Toward Standardization.

Authors:  Francesca Mandino; Domenic H Cerri; Clement M Garin; Milou Straathof; Geralda A F van Tilborg; M Mallar Chakravarty; Marc Dhenain; Rick M Dijkhuizen; Alessandro Gozzi; Andreas Hess; Shella D Keilholz; Jason P Lerch; Yen-Yu Ian Shih; Joanes Grandjean
Journal:  Front Neuroinform       Date:  2020-01-22       Impact factor: 4.081

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.