Literature DB >> 17899600

Combined functional and viability cardiac MR imaging in a single breathhold.

El-Sayed H Ibrahim1, Matthias Stuber, Dara L Kraitchman, Robert G Weiss, Nael F Osman.   

Abstract

The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI pulse sequence in a single short breathhold. The method was validated against conventional inversion-recovery (IR) DE images for identifying regions of myocardial infarction (MI). The method was based on the acquisition of three consecutive images of the same anatomical slice. One image has T(1)-weighted contrast in which infarction appears bright. The two other images are used to construct an anatomical image of the heart, which is combined with the first image to produce a black-blood viability image. However, using appropriate modulation and demodulation frequencies, the latter two images bear useful information about myocardial deformation that results in a cardiac strain-encoding (SENC) functional image. In this work, a method is proposed for obtaining three consecutive SENC images in a single acquisition that can be combined to produce a composite image of the heart, which shows both functional and viability information. The proposed technique reduces scan time by one-half, compared with separate acquisitions of functional and viability images, and alleviates misregistration problems caused by separate breathholds.

Entities:  

Mesh:

Year:  2007        PMID: 17899600     DOI: 10.1002/mrm.21390

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

Review 1.  Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.

Authors:  El-Sayed H Ibrahim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

Review 2.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

3.  Identification of different heart tissues from MRI C-SENC images using an unsupervised multi-stage fuzzy clustering technique.

Authors:  El-Sayed H Ibrahim; Robert G Weiss; Matthias Stuber; Amy E Spooner; Nael F Osman
Journal:  J Magn Reson Imaging       Date:  2008-08       Impact factor: 4.813

4.  Simultaneous myocardial strain and dark-blood perfusion imaging using a displacement-encoded MRI pulse sequence.

Authors:  Yuan Le; Ashley Stein; Colin Berry; Peter Kellman; Eric E Bennett; Joni Taylor; Katherine Lucas; Rael Kopace; Christophe Chefd'Hotel; Christine H Lorenz; Pierre Croisille; Han Wen
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.