Literature DB >> 17898984

[Reprocessing rigid and flexible cystoscopes in urology: recommendations for ambulant practices].

U Heudorf1, U Otto, O Leiss, M Wiesel.   

Abstract

Infection control visits of the public health department in the city of Frankfurt a.M., Germany, revealed the need for easily understandable and practicable information and recommendations for the reprocessing of rigid and flexible cystoscopes. Based on the German Guidelines for reprocessing medical devices and cystoscopes practical information and examples of specific reprocessing schedules are given in this article in order to enable the personnel in the practices to comply with the guidelines and to prevent nosocomial infections.

Entities:  

Mesh:

Year:  2007        PMID: 17898984     DOI: 10.1007/s00120-007-1542-z

Source DB:  PubMed          Journal:  Urologe A        ISSN: 0340-2592            Impact factor:   0.639


  23 in total

1.  Guidelines on cleaning and disinfection in GI endoscopy. Update 1999. The European Society of Gastrointestinal Endoscopy.

Authors: 
Journal:  Endoscopy       Date:  2000-01       Impact factor: 10.093

Review 2.  Establishing the shelf life of flexible colonoscopes.

Authors:  Robin Riley; Christine Beanland; Henk Bos
Journal:  Gastroenterol Nurs       Date:  2002 May-Jun       Impact factor: 0.978

3.  ESGE/ESGENA technical note on cleaning and disinfection.

Authors:  J-F Rey; A Kruse; Christiane Neumann
Journal:  Endoscopy       Date:  2003-10       Impact factor: 10.093

4.  [Not Available].

Authors: 
Journal:  Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz       Date:  2002-04       Impact factor: 1.513

5.  Rigid versus flexible cystoscopy. A controlled trial of patient tolerance.

Authors:  G M Flannigan; J S Gelister; J G Noble; E J Milroy
Journal:  Br J Urol       Date:  1988-12

Review 6.  Prevalence of nosocomial infections in hospitals in Norway, 2002 and 2003.

Authors:  H M Eriksen; B G Iversen; P Aavitsland
Journal:  J Hosp Infect       Date:  2005-05       Impact factor: 3.926

7.  The community-based morbidity of flexible cystoscopy.

Authors:  D M Burke; D C Shackley; P H O'Reilly
Journal:  BJU Int       Date:  2002-03       Impact factor: 5.588

8.  Urinary tract infection and patient satisfaction after flexible cystoscopy and urodynamic evaluation.

Authors:  Y Z Almallah; C D Rennie; J Stone; M J Lancashire
Journal:  Urology       Date:  2000-07       Impact factor: 2.649

Review 9.  Hospital-acquired urinary tract infection.

Authors:  J Kalsi; M Arya; P Wilson; A Mundy
Journal:  Int J Clin Pract       Date:  2003-06       Impact factor: 2.503

10.  Nine episodes of anaphylaxis following cystoscopy caused by Cidex OPA (ortho-phthalaldehyde) high-level disinfectant in 4 patients after cytoscopy.

Authors:  William N Sokol
Journal:  J Allergy Clin Immunol       Date:  2004-08       Impact factor: 10.793

View more
  1 in total

1.  [Disinfection and recontamination of rigid endoscopes: improved safety using an immersion quiver system].

Authors:  C Rohrmeier; J Strutz; W Schneider-Brachert
Journal:  HNO       Date:  2014-10       Impact factor: 1.284

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.