Literature DB >> 17898282

Dichoptic stimulation improves detection of glaucoma with multifocal visual evoked potentials.

Hemamalini Arvind1, Alexander Klistorner, Stuart Graham, John Grigg, Ivan Goldberg, Asya Klistorner, Frank A Billson.   

Abstract

PURPOSE: To determine whether simultaneous binocular (dichoptic) stimulation for multifocal visual evoked potentials (mfVEP) detects glaucomatous defects and decreases intereye variability.
METHODS: Twenty-eight patients with glaucoma and 30 healthy subjects underwent mfVEP on monocular and dichoptic stimulation. Dichoptic stimulation was presented with the use of virtual reality goggles (recording time, 7 minutes). Monocular mfVEPs were recorded sequentially for each eye (recording time, 10 minutes).
RESULTS: Comparison of mean relative asymmetry coefficient (RAC; calculated as difference in amplitudes between eyes/sum of amplitudes of both eyes at each segment) on monocular and dichoptic mfVEP revealed significantly lower RAC on dichoptic (0.003 +/- 0.03) compared with monocular testing (-0.02 +/- 0.04; P = 0.002). In all 28 patients, dichoptic mfVEP identified defects with excellent topographic correspondence. Of 56 hemifields (28 eyes), 33 had Humphrey visual field (HFA) scotomas, all of which were detected by dichoptic mfVEP. Among 23 hemifields with normal HFA, two were abnormal on monocular and dichoptic mfVEP. Five hemifields (five patients) normal on HFA and monocular mfVEP were abnormal on dichoptic mfVEP. In all five patients, corresponding rim changes were observed on disc photographs. Mean RAC of glaucomatous eyes was significantly higher on dichoptic (0.283 +/- 0.18) compared with monocular (0.199 +/- 0.12) tests (P = 0.0006).
CONCLUSIONS: Dichoptic mfVEP not only detects HFA losses, it may identify early defects in areas unaffected on HFA and monocular mfVEP while reducing testing time by 30%. Asymmetry was tighter among healthy subjects but wider in patients with glaucoma on simultaneous binocular stimulation, which is potentially a new tool in the early detection of glaucoma.

Entities:  

Mesh:

Year:  2007        PMID: 17898282     DOI: 10.1167/iovs.07-0318

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  3 in total

1.  Simultaneous recording of multifocal VEP responses to short-wavelength and achromatic stimuli.

Authors:  Xian Zhang; Min Wang; Donald C Hood
Journal:  Doc Ophthalmol       Date:  2010-05-25       Impact factor: 2.379

Review 2.  Terrestrial health applications of visual assessment technology and machine learning in spaceflight associated neuro-ocular syndrome.

Authors:  Joshua Ong; Alireza Tavakkoli; Nasif Zaman; Sharif Amit Kamran; Ethan Waisberg; Nikhil Gautam; Andrew G Lee
Journal:  NPJ Microgravity       Date:  2022-08-25       Impact factor: 4.970

3.  Dichoptic Spatial Contrast Sensitivity Reflects Binocular Balance in Normal and Stereoanomalous Subjects.

Authors:  Mirella Telles Salgueiro Barboni; Otto Alexander Maneschg; János Németh; Zoltán Zsolt Nagy; Zoltán Vidnyánszky; Éva M Bankó
Journal:  Invest Ophthalmol Vis Sci       Date:  2020-09-01       Impact factor: 4.799

  3 in total